Registration Dossier

Physical & Chemical properties

Particle size distribution (Granulometry)

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2017
Reliability:
1 (reliable without restriction)
Qualifier:
according to
Guideline:
other: GB/T 6288-1986 Determination of particle size for granular molecular sieve
GLP compliance:
no
Type of method:
sieving
Type of distribution:
mass based distribution
Mass median aerodynamic diameter:
>= 0.18 - <= 0.85 mm
Percentile:
D50
Remarks on result:
other: Migrated from fields under 'Mass median diameter' as D50 percentile. No source field for Standard deviation.
No.:
#1
Size:
> 0.18 mm
Distribution:
ca. 91.6 %
No.:
#2
Size:
<= 0.18 mm
Distribution:
ca. 8.4 %
Conclusions:
Based on the test results, the particle size with most amount of sample was 0.18mm~0.85mm, parallel tests were taken, and the weight contents of screen residue with size larger than 0.18 mm were 92.95% and 90.15%, the average result was 91.6%.

Description of key information

Additional information

Based on the test results, the particle size with most amount of sample was 0.18mm~0.85mm, parallel tests were taken, and the weight contents of screen residue with size larger than 0.18 mm were 92.95% and 90.15%, the average result was 91.6%.