Endpoint:
flammability, other
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2017
Reliability:
1 (reliable without restriction)
Qualifier:
according to
Guideline:
EU Method A.10 (Flammability (Solids))
GLP compliance:
no
Specific details on test material used for the study:
Stopwatch;
Base plate: an impervious, non-combustible, low heat-conducting plate, used to support the sample train; such as an ceramic plate, etc. Its length should be more than 270 mm and breadth be more than 40 mm;
Electromagnetic ignitor: made by a silicon carbon rod, minimum temperature 1000℃;
Solid burning rate tester: equipped with a specified mould used to form the sample train, inner long 250 mm.

Phenomena and results from two independent preliminary screening tests, were identical as following: the sample does not ignite during burning its one end for 2 min.

It can be ascertained that the sample is not a flammable solid based on the results of the preliminary screening test.

Conclusions:
The sample is not a flammable solid.

Description of key information

Key value for chemical safety assessment

Additional information

The sample is not a flammable solid.