Registration Dossier

Administrative data

Endpoint:
oxidising solids
Study period:
17 June 2014 - 05 September 2014
Data waiving:
study scientifically not necessary / other information available
Justification for data waiving:
the study does not need to be conducted because there are no chemical groups present in the molecule which are associated with oxidising properties and hence, the classification procedure does not need to be applied

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2014
Report Date:
2014

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to
Guideline:
other: UN ST/SG/AC.10/11/Rev.5: Recommendations on the Transport of Dangerous Goods, Manual of Tests and Criteria, Appendix 6 "Screening procedures" (2009)
Deviations:
no
Qualifier:
according to
Guideline:
EU Method A.17 (Oxidising Properties (Solids))
Version / remarks:
(2008)
Deviations:
no
GLP compliance:
yes (incl. certificate)

Test material

Reference
Name:
Unnamed
Type:
Constituent
Test material form:
solid: particulate/powder
Remarks:
migrated information: powder
Details on test material:
- Name of test material (as cited in study report): [trade name given]
- Substance type: mono-constituent
- Description: white powder
- Storage condition of test material: at room temperature in the dark

Results and discussion

Any other information on results incl. tables

Statement

 

According to the UN, a test substance is considered an oxidizing substance when the burning time of a mixture of the substance and cellulose in a 4:1 or 1:1 sample-to-cellulose ratio (by mass) is less than or equal to the mean burning time of a 3:7 reference mixture (by mass) of potassium bromate and cellulose.

 

The molecular structure of the test substance does not contain groups that act as an oxidizing agent. The molecular structures of impurities were not taken into account.

Applicant's summary and conclusion

Interpretation of results:
other: no oxidising properties
Remarks:
Migrated information
Conclusions:
In a GLP statement in accordance with UN-MTC Appendix 6 and EC A.17, it was concluded that the substance has no oxidizing properties as it lacks structural alerts.