Registration Dossier

Administrative data

Endpoint:
flash point
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
1996
Report Date:
1996

Materials and methods

Test guideline
Qualifier:
according to
Guideline:
other: 92/69/EEC, A9 (Pensky-Martens, ASTM-D93-100)
GLP compliance:
yes
Type of method:
closed cup

Test material

Reference
Name:
Unnamed
Type:
Constituent

Results and discussion

Flash point
Flash point:
126 °C
Atm. press.:
1 012 mBar

Applicant's summary and conclusion