Registration Dossier

Administrative data

Endpoint:
vapour pressure
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
1995
Report Date:
1995

Materials and methods

Test guideline
Qualifier:
according to
Guideline:
other: 92/69/EEC, A4 (Vapour pressure balance)
GLP compliance:
yes

Test material

Reference
Name:
Unnamed
Type:
Constituent

Results and discussion

Vapour pressureopen allclose all
Temp.:
25 °C
Vapour pressure:
0.75 Pa
Remarks on result:
other: First vapour pressure
Temp.:
36 °C
Vapour pressure:
2.26 Pa
Remarks on result:
other: Second vapour pressure

Applicant's summary and conclusion