Registration Dossier

Physical & Chemical properties

Viscosity

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
viscosity
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2015
Reliability:
1 (reliable without restriction)
Qualifier:
according to
Guideline:
other: internal monograph
Principles of method if other than guideline:
The viscosity of the substance CAE was measured using Brookfield Digital Viscometer model DV-ll+. The Brookfield viscometer measures viscosity by determining the force required to rotate a spindle in a fluid.
Speed: 100 rpm
Protocol: dynamic viscosity is measured during 1 minute on a sample previously stabilized 2 hours at 30°C.
GLP compliance:
yes
Type of method:
rotational viscometer (dynamic)
Temp.:
other: 30.0°C
Parameter:
dynamic viscosity (in mPa s)
Value:
30
Conclusions:
The dynamic viscosity of the substance CAE measured by rotational viscometer was 30 mPa*s at 30°C.
Executive summary:

The dynamic viscosity of the substance CAE was measured by rotational viscometer at 30°C.

Description of key information

The dynamic viscosity of the substance CAE measured by rotational viscometer was 30 mPa*s at 30°C.

Key value for chemical safety assessment

Viscosity:
30 mPa · s (dynamic)
at the temperature of:
30 °C

Additional information