Endpoint:
flammability
Remarks:
Pyrophoric liquids/solids (migrated from section 'Flammability')
Type of information:
experimental study
Adequacy of study:
key study
Study period:
Not reported
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: Study conducted according with EPA OPPTS 830.6315
Justification for data waiving:
other:
Cross-referenceopen allclose all
Reason / purpose for cross-reference:
reference to same study
Reason / purpose for cross-reference:
reference to other study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
1985

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
EPA OPPTS 830.6315 (Flammability)
Deviations:
not specified
Principles of method if other than guideline:
Not applicable
GLP compliance:
not specified

Test material

Constituent 1
Chemical structure
Reference substance name:
N-(carboxymethyl)-N-(phosphonomethyl)glycine
EC Number:
227-824-5
EC Name:
N-(carboxymethyl)-N-(phosphonomethyl)glycine
Cas Number:
5994-61-6
Molecular formula:
C5H10NO7P
IUPAC Name:
2-[(carboxymethyl)(phosphonomethyl)amino]acetic acid
Details on test material:
- Name of test material (as cited in study report): N-(phosphonomethyl) iminodiacetic acid (glyphosate intermediate)

Results and discussion

Pyrophoric solids
Test procedure:
ignition time on contact with air
Remarks:
Ignition on contact with air refers to either Pyrophoric solids or Pyrophoric liquids depending on physical state (migrated information).
Remarks on result:
no ignition on contact with air (not further specified)
Remarks:
corresponding to 'no' in migrated source record.
Pyrophoric liquids
Test procedure:
ignition time on contact with air
Remarks:
Ignition on contact with air refers to either Pyrophoric solids or Pyrophoric liquids depending on physical state (migrated information).
Remarks on result:
no ignition on contact with air (not further specified)
Remarks:
corresponding to 'no' in migrated source record.

Any other information on results incl. tables

None

Applicant's summary and conclusion

Interpretation of results:
other: Not combustible under normal conditions
Conclusions:
The test material is not combustible under normal conditions.
Executive summary:

The test material is not combustible under normal conditions.