Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Guidance on Safe Use

Guidance on Safe Use

Currently viewing:

Administrative data

First-aid measures

General information

Remove soiled or soaked clothing immediately

After inhalation

Remove the casualty into fresh air and keep him calm.

In the event of symptoms seek medical advice.

After contact with skin

In case of contact with skin wash off immediately with soap and water

After contact with eyes

In case of contact with eyes rinse thoroughly with plenty of water and seek medical advice

After ingestion

Summon a doctor immediately.

Fire-fighting measures

Suitable extinguishing media

water spray jet

foam

Extinguishing media that must not be used for safety reasons

dry powder

carbon dioxide

strong water jet

Special hazards from the substance itself, its combustion products or from its vapours

In case of fires, hazardous combustion gases are formed: Carbon monoxide (CO)

Nitrous gases (NOx)

Special protective equipment for firefighting

Use self-contained breathing apparatus

Accidental release measures

Personal precautions

Avoid dust formation.

Wear suitable personal protective equipment.

Keep away sources of ignition.

Environmental precautions

Do not allow to enter drains or waterways

Methods for cleaning up/taking up

Pick up mechanically. Rinse away rest with water.

Handling and storage

Advice on safe handling

Keep the formation and deposition of dust to a minimum.

Open and handle container with care.

Advice on protection against fire and explosion

Take precautionary measures against electrostatic charges - earthing necessary during

loading operations.

Keep away from sources of ignition - refrain from smoking.

The product is capable of a dust explosion.

Dust explosion class :

ST2 Capable of dust explosion

Transport information

Land transport (UN RTDG/ADR/RID)

UN number:
UN 3077
Shipping information
Proper shipping name and description:
Environmentally hazardous substance, solid, n.o.s.
Chemical name:
PIROCTON OLAMINE
Language:
English
SpecialProvisionsopen allclose all

Inland waterway transport (UN RTDG/ADN(R))

UN number:
UN 3077
Shipping information
Proper shipping name and description:
Environmentally hazardous substance, solid, n.o.s.
Chemical name:
PIROCTON OLAMINE
Language:
English
Special provisions / remarks
Remarks:
Shipment permitted

Marine transport (UN RTDG/IMDG)

UN number:
UN 3077
Shipping information
Proper shipping name and description:
Environmentally hazardous substance, solid, n.o.s.
Chemical name:
PIROCTON OLAMINE
Marine pollutant
Special provisions / remarks
Remarks:
Shipment permitted

Air transport (UN RTDG/ICAO/IATA)

UN number:
UN 3077
Shipping information
Proper shipping name and description:
Environmentally hazardous substance, solid, n.o.s.
Chemical name:
PIROCTON OLAMINE
Special provisions / remarks
Remarks:
Shipment permitted
SpecialProvisionsopen allclose all

Exposure controls / personal protection

Occupational exposure controls

General protective measures

Avoid contact with eyes and skin

Do not inhale dust

Hygiene measures

Observe the usual precautions when handling chemicals.

Respiratory protection :

Use respiratory protection in case of insufficient exhaust ventilation or prolonged exposure Full mask to standard DIN EN 136 Particle filter P, to standard DIN EN 143 The use of filter apparatus presupposes that the environment atmosphere contains at least 17% oxygen by volume, and does not exceed the maximum gas concentration, usually 0.5% by volume. Relevant guidelines to be considered include EN 136/141/143/371/372 as well as other national regulations.

Hand protection :

For long-term exposure: Butyl rubber gloves. Minimum thickness (glove): not determined With solid dry substances permeation is not to be expected, therefore the breakthrough-time for this protective glove has not been measured.

For short-term exposure (splash protection): Nitrile rubber gloves. Minimum thickness (glove): not determined

With solid dry substances permeation is not to be expected, therefore the breakthrough-time for this protective glove has not been measured. These types of protective gloves are offered by various manufacturers. Please note the manufacturers´ detailed statements, especially about the minimum thickness and the minimum breakthrough time. Consider also the particular working conditions under which the gloves are being used.

Eye protection :

Depending on the risk, wear sufficient eye protection (safety glasses with side protection or goggles, and if necessary, face shield.)

Body protection :

protective clothing

Stability and reactivity

Thermal decomposition : approx. 240 °C (Heating rate : 10 K/min)

Hazardous reactions

No hazardous reactions when stored and handled according to prescribed instructions.

Disposal considerations

Product

In accordance with local authority regulations, take to special waste incineration plant