Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Link to relevant study record(s)

Description of key information

The test on oxidizing properties of cesium iodide was perfomed according to the EU Method A.17. The highest burning rate of 3.28 mm/s was obtained with the mixture of 10 % test item : 90 % cellulose. This rate was definitely lower than the highest rate of the reference mixtures (3.63 mm/s). With regard to all test results the test item is assessed to have no oxidizing properties.

Key value for chemical safety assessment

Oxidising properties:
no

Additional information

Justification for classification or non-classification

Based on the results of the "oxidising properties" test, the test item cesium iodide is not classified according to Regulation (EC) No 1272/2008 (CLP) with respect to oxidising properties.