Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Ecotoxicological information

Toxicity to microorganisms

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
activated sludge respiration inhibition testing
Type of information:
experimental study
Adequacy of study:
key study
Study period:
1999-04-19 to 1999-04-21
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
other: ETAD 103
Deviations:
not specified
Qualifier:
according to guideline
Guideline:
OECD Guideline 209 (Activated Sludge, Respiration Inhibition Test
Version / remarks:
not specified
Deviations:
no
Qualifier:
according to guideline
Guideline:
ISO 8192 (Water quality - Test for inhibition of oxygen consumption by activated sludge for carbonaceous and ammonium oxidation)
Version / remarks:
not specified
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Specific details on test material used for the study:
- CAS no.: 22224-92-6
Analytical monitoring:
no
Details on sampling:
analytical monitoring not performed
Vehicle:
no
Details on test solutions:
PREPARATION AND APPLICATION OF TEST SOLUTION
- Method: test item directly weighed in
- Controls: negative control, reference control, physiochemical oxygen consumption control (sterile control)
- Test concentration separation factor: < 2
- Evidence of undissolved material: not specified
Test organisms (species):
activated sludge of a predominantly domestic sewage
Details on inoculum:
- Name and location of sewage treatment plant where inoculum was collected: aeration tank of a waste water plant treating predominantly domestic sewage (Wupper area water authority)
- Pretreatment: none
- Initial biomass concentration: 320 mg activated sludge/L
Test type:
static
Water media type:
freshwater
Limit test:
no
Total exposure duration:
3 h
Post exposure observation period:
Post exposure observation not performed
Hardness:
not specified
Test temperature:
20.8 - 20.9 °C
pH:
7.8 - 8.0
Dissolved oxygen:
7.06 (mean, start) to 4.18 (mean, end) mg/L
Salinity:
not applicable
Conductivity:
not specified
Nominal and measured concentrations:
Nominal: 560, 1000, 1800, 3200 and 5600 mg/L; measured values are not available
Details on test conditions:
TEST SYSTEM
- Test vessel: not specified
- Aeration: permanent aeration
- No. of vessels per concentration: 1
- No. of vessels per control: 2 (negative control) and 1 per concentration of reference control
- No. of vessels per abiotic control: 1
Reference substance (positive control):
yes
Remarks:
3.5-Dichlorophenol
Key result
Duration:
3 h
Dose descriptor:
EC50
Effect conc.:
2 300 mg/L
Nominal / measured:
nominal
Conc. based on:
test mat.
Basis for effect:
inhibition of total respiration

The results for the negative controls of the experimental study were re-assessed by Lattimore (2017) as requested by the Rapporteur Member State in the course of the EU PP Renewal Dossier for Fenamiphos.


Control 1 mg O2/L/hour = (((5.0-2.5)/5)*60)/0.32 = 93.75


Control 2 mg O2/L/hour = (((5.6-2.5)/6)*60)/0.32 = 96.875


Mean = 95.3 & CV = 2.3%


It can therefore be concluded that the results of the study are valid and the endpoints suitable for risk assessment.

Validity criteria fulfilled:
yes
Conclusions:
In a study saccording to OECD TG 209 the 3-hour EC50 of the test item was determined as 2030 mg/L, indicating no toxicity of fenamiphos to activated sludge.
Executive summary:

In a valid GLP-comliant study according to OECD TG 209 activated sludge of a laboratory waste water treatment plant was exposed for 3 hours to nominal test item concentrations ranging from 560 to 5600 mg test substance/L. The EC50 was determined as 2030 mg/L, indicating no toxicity of fenamiphos to activated sludge. 

Description of key information

In a study saccording to OECD TG 209 the 3-hour EC50 of the test item was determined as 2030 mg/L, indicating no toxicity of the test substance to activated sludge.

Key value for chemical safety assessment

EC50 for microorganisms:
2 030 mg/L

Additional information

In a valid GLP-comliant study according to OECD TG 209 activated sludge of a laboratory waste water treatment plant was exposed for 3 hours to nominal test item concentrations ranging from 560 to 5600 mg test substance/L. The EC50 was determined as 2030 mg/L, indicating no toxicity of the test substance to activated sludge (Müller, 1999).