Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
oxidising liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
April 8th 2021
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2021
Report date:
2021

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
EU Method A.21 (Oxidising Properties (Liquids))
Deviations:
no
GLP compliance:
yes (incl. QA statement)

Test material

Constituent 1
Chemical structure
Reference substance name:
Reaction mass of oxybispropanediol and tetraglycerol and triglycerol, esterification products with lactic acid and lauric acid
Molecular formula:
not applicable - UVCB substance
IUPAC Name:
Reaction mass of oxybispropanediol and tetraglycerol and triglycerol, esterification products with lactic acid and lauric acid
Specific details on test material used for the study:
Test item name: Finestar 2009
CAS Number: 2225876-48-0
Water solubility: soluble in water
Molecular formula: C12 H22 O8
Molecular weight: 294.30
Batch/Lot number: 3253082031
analyzed purity: 100% active
Saponification value: 45.87
Date of manufacture: August 27, 2020
Date of expiry: August 26, 2021
Appearance: Pale yellow viscous liquid
Storage temperature: Room temperature (15 to 30°C)
Storage condition: Keep away from light, moisture, and oxidizing - reducing chemicals
Storage container: Keep in original container

Study design

Contact with:
powdered cellulose
Duration of test (contact time):
13.493 s

Results and discussion

Test results (Oxidising liquids)
Sample tested:
test mixture 1:1
Parameter:
mean pressure rise time
Result:
13.493 s

Any other information on results incl. tables

Determination of Pressure Rise Time












































































































    Column5Column6Column7Column8Column9Column10Column11
Reference Mixture    Test Mixture     
ReplicationCellulose Powder (g)Nitric acid (g)Pressure Rise Time (Second) (Rn)% DifferenceReplicationCellulose Powder (g)Test item (g)Pressure Rise Time (second) (Rn)% Difference
R12.50062.50610.975-12.004T12.50712.500311.73 -13.066
R22.50282.50291.110.181T22.50432.508511.895 -11.843
R32.50652.50481.28.303T32.50032.506812.75 -5.507
R42.50752.50221.045-5.686T42.50252.509715.91 17.913
R52.5072.50791.219.206T52.50462.504715.18 12.503

Applicant's summary and conclusion

Interpretation of results:
GHS criteria not met
Executive summary:

The present study was conducted according to:
EC 2008: The Commission Regulation (EC) No 440/2008 of 30 May 2008 laying down Test Methods
pursuant to Regulation (EC) No 1907/2006 of the European Parliament and of the Council on the
Registration, Evaluation, Authorisation and Restriction of Chemicals (REACH), A.21. “Oxidising
Properties (Liquids)”, Official Journal No L 152, 31/05/2008.


 


The mean pressure-rise time for the reference mixture (cellulose and 65% nitric
acid) was 1.108 seconds.
The mean pressure-rise time for the test mixture (cellulose and test item) was 13.493 seconds.
As the mean pressure-rise time of the test mixture was significantly more than the reference mixture, it is
concluded that Finester 2009 is “Non-Oxidising in Nature”.