Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
Not reported
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
ISO 2719 (Determination of flash point - Pensky-Martens closed cup method)
Version / remarks:
2002
GLP compliance:
no
Type of method:
closed cup
Key result
Flash point:
92 °C
Atm. press.:
1 atm

First reported value: 92º C

Second reported value: 92º C

Third reported value: 92º C

Mean value: 92º C

Interpretation of results:
GHS criteria not met
Conclusions:
Under the conditions of the study the flash point of the test material was determined to be 92 °C at 1 atm.
Executive summary:

The flash point of the test material was determined in accordance with ISO 2719:2002 (Determination of flash point - Pensky-Martens closed cup method). Under the conditions of the study the flash point of the test material was determined to be 92 °C at 1 atm.

Description of key information

In order to determine the flash point of the test item, the ISO 2719:2002 Determination of flash point – Pensky-Martens closed cup method was followed.

The flash point of the test item is 92°C.

Key value for chemical safety assessment

Flash point at 101 325 Pa:
92 °C

Additional information

In order to determine the flash point of the test item, the ISO 2719:2002 Determination of flash point – Pensky-Martens closed cup method was followed.

The flash point of the test item is 92°C.