Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Vapour pressure

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
vapour pressure
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: Comparable to guideline study with acceptable restrictions (e.g. non-GLP)
Qualifier:
according to guideline
Guideline:
other: DIN-EN 13016-2
GLP compliance:
no
Other quality assurance:
other: DIN EN ISO 90001:2008, 14001:2005
Type of method:
static method
Remarks:
MiniVap (Fa. Grabner-Instruments)
Temp.:
20 °C
Vapour pressure:
2 hPa
Remarks on result:
other: extrapolated value based on experimental results

Experimental results (12 measurements at different temperatures):

Temperature [°C] Vapour pressure [hPa] 
95 57 
100 68 
105 81
110 97 
115

115 

 120  136
 125 162 
 130  191
 135  225
 140  264
 145 308 
 150 360 

 

Regression equation to determine the vapour pressure:

y=-2280.9x + 7.9408 with R²=0.9998 and y=log(p) with p=vapour pressure in hPa and x=1/T in K

Result from the above equation: Vapour pressure (20°C) = 2 hPa

Conclusions:
Extrapolated vapour pressure: 2 hPa at 20°C
Executive summary:

Based on DIN EN 13016 -2, the vapour pressure at 20 °C has been linearly extrapolated on the basis of twelve experimentally determined values at 95, 100, 105, 110, 115, 120, 125, 130, 135, 140, 145, and 150 °C. The resulting vapour pressure at 20 °C has been determined to be 2 hPa.

Description of key information

Based on DIN EN 13016 -2, the vapour pressure at 20 °C has been linearly extrapolated on the basis of twelve experimentally determined values at 95, 100, 105, 110, 115, 120, 125, 130, 135, 140, 145, and 150 °C. The resulting vapour pressure at 20 °C has been determined to be 2 hPa.

Key value for chemical safety assessment

Vapour pressure:
2 hPa
at the temperature of:
20 °C

Additional information