Registration Dossier

Administrative data

First-aid measures

Emergency measure - Inhalation: Symptomatic treatment, if necessary.
Emergency measure - Eyes: Rinse immediately with water or an eyewash solution for at
least 10 minutes. Seek medical attention.
Emergency measure - Skin: Wash with water. If symptoms occur seek medical attention.
Emergency measure - Ingestion: Seek medical advice.

Fire-fighting measures

Recommended extinguishing agent: Water, foam, carbon dioxide or dry powder may be ued.

Product arising from burning: Products of combustion may contain oxides of carbon and
nitrogen together with hydrogen chloride and some soot.

Product determined by test: N

Protective equipment: Protective clothing should be worn together with a
self-contained breathing apparatus.

Accidental release measures

Emergency measures in case of spillage: Isolate spillage and remove personnel from the afected area.
Moisten spillage with water, sweep up and transfer to waste
containers for disposal. Dispose of at a landfill site or by
incineration at a suitable facility in accordance with local
regulations.

Handling and storage

Handling: Observe the usual precautions for handling organic
chemicals. Avoid ingestion, inhalation and contact with skin
and eyes. Gloves should be worn. If dust is generated a
respirator complying to BS6016 should be used.

Storage: No special precautions.

Transport information

Shippingopen allclose all
SpecialProvisionsopen allclose all
Shippingopen allclose all
Remarksopen allclose all

Marine transport (IMDG)

Remarksopen allclose all

Air transport ICAO/IATA

Remarks
Transport: No special precautions.
SpecialProvisionsopen allclose all

Exposure controls / personal protection

Stability and reactivity

Danger other than fire: In common with many other organic chemicals in powder form,
the substance could form flammable dust clouds in air.

Chemical reaction with water: None reported.

Dust explosion determined by test: N

Disposal considerations

Industry - Possibility of recovery/recycling: Recovery for recycling is not possible.

Industry - Possibility of neutralisation: None known

Industry - Possibility of destruction: controlled discharge: The substance can be disposed of at a controlled landfill
site. Do not discharge into the water. (A650)

Industry - Possibility of destruction - incineration: Recommended method. The substance can be disposed of by
incineration at a suitable facility using temperatures above
950 deg C. Waste gas treatment to remove nitrogen oxides and
hydrogen chloride should be fitted. (A661)

Industry - Possibility of destruction - water purification: Not recommended in view of the low solubility, high
stability and the effect on anaerobic sewage treatment.

Public at large - Possibility of recovery/recycling: Recovery from articles is not possible.

The substance itself will not enter the public domain.

Public at large - Possibility of neutralisation: Not applicable.

Public at large - Possibility of destruction: controlled discharge: Articles containing the substance may be disposed of as
domestic waste.