Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
June 18, 2012
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: Well conducted study, according to EU guideline A9, under Internal Management system and certificate of analysis included in the report.
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
Version / remarks:
May 31, 2008
Qualifier:
according to guideline
Guideline:
ISO No., other: ASTM D93-08, Standard Test Methods for Flash Point by Pensky-Martens Closed Cup Tester, 2008
GLP compliance:
no
Type of method:
closed cup
Key result
Flash point:
142 °C
Atm. press.:
101.3 kPa

Calibration and accuracy

The measured value with n-undecane after correction for atmospheric pressure was 68.2°C.

This value is within the acceptance limits.

 

The accuracy of the method varies according to the flash point range used. The maximum estimated accuracy is ±2°C.

 

The estimated accuracy of the manometer ± 0.1 kPa.

 

Flash point of test substance

The determination of the flash point of the test substance was carried out in duplicate.

- first result                             : 149.0°C

- second result                         : 135.2°C

- atmospheric pressure             : 101.1kPa

- corrected average flash point  : 142.1°C (standard deviation 9.8°C, n=2)

 

This means that the flash point of the test substance is 142°C.

 

Interpretation of results:
GHS criteria not met
Conclusions:
The flash point of Decanoyl Chloride is 142°C at 101.3 kPa. 
Executive summary:

The flash point by Pensky-Martens closed cup of decanoyl chloride was determined according to EC Regulation No 440/2008, Guideline A.9 , and according to ASTM D93 and in accordance with European Chemicals Agency (ECHA), Guidance on information requirements and chemical safety assessment, Chapter R.7a, Endpoint specific guidance, May 2008.

The flash point of Decanoyl Chloride is 142°C at 101.3 kPa.

Description of key information

The flash point of Decanoyl Chloride is 142 °C at 101.3 kPa .

Key value for chemical safety assessment

Flash point at 101 325 Pa:
142 °C

Additional information