Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Referenceopen allclose all

Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
09 Mar 2015
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
guideline study with acceptable restrictions
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
Qualifier:
according to guideline
Guideline:
ISO 2719 (Determination of flash point - Pensky-Martens closed cup method)
Version / remarks:
2002
GLP compliance:
no
Type of method:
closed cup
Flash point:
191 °C
Atm. press.:
974 hPa

Results

 

Test

Measured value [°C]

Calculated value [°C]

Preliminary test

-

-

1

192.1

193.0

2

188.2

189.0

 

Measured value: 191.0 °C

Conclusions:
A flash point value of 191.0 °C at 974 hPa was determined in a reliable study conducted according to an appropriate test protocol. It was not compliant with GLP.
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
supporting study
Study period:
09 Mar 2015
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
guideline study with acceptable restrictions
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
Qualifier:
according to guideline
Guideline:
ISO 3679 (Determination of flash point - Rapid equilibrium closed cup method)
Version / remarks:
2004
GLP compliance:
no
Type of method:
equilibrium method closed cup
Flash point:
> 110 °C
Atm. press.:
97.4 hPa

Results

 

Test

Test series temperature [° C]

Result

1

80

negative

2

90

negative

3

100

negative

4

110

negative

 

Measured value: > 110 °C

Determination of the corrected flash-point:

 

TC = T0+ 0.25 x (101.3 – p)

TC = corrected flash point to the standard atmospheric pressure (101.3 kPa)

T0= measured flash point at actual atmospheric pressure

p = actual atmospheric pressure [kPa]

Conclusions:
A flash point value of > 110 °C at 967 hPa was determined in a reliable study conducted according to an appropriate test protocol. It was not compliant with GLP.

Description of key information

191 °C at 974 hPa (EU Method A.9, Pensky Martens closed cup)

Key value for chemical safety assessment

Flash point at 101 325 Pa:
191 °C

Additional information

The key study is supported by a flash point value of >110 °C determined by equilibrium method closed cup method according to EU Method A.9.