Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Partition coefficient

Currently viewing:

Administrative data

Link to relevant study record(s)

Referenceopen allclose all

Endpoint:
partition coefficient
Type of information:
experimental study
Adequacy of study:
key study
Study period:
29 Nov 2018 - 01 Oct 2019
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
OECD Guideline 117 (Partition Coefficient (n-octanol / water), HPLC Method)
Version / remarks:
23 November 2004
Deviations:
no
Qualifier:
according to guideline
Guideline:
other: EC Guideline A.24. Partition Coefficient (n-octanol/water), High Performance Liquid Chromatography (HPLC) Method.
Version / remarks:
March 04, 2016
Deviations:
no
Qualifier:
according to guideline
Guideline:
EPA OPPTS 830.7570 (Partition Coefficient, n-octanol / H2O, Estimation by Liquid Chromatography)
Version / remarks:
August 1996.
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Type of method:
HPLC method
Partition coefficient type:
octanol-water
Specific details on test material used for the study:
Identification: Esacure A 198
Physical Description: White powder
Purity/Composition: 99.2%
Storage Conditions: At room temperature protected from light desiccated
Analytical method:
high-performance liquid chromatography
Type:
log Pow
Partition coefficient:
4.2
Temp.:
35 °C
pH:
7
Type:
log Pow
Partition coefficient:
4.3
Temp.:
35 °C
pH:
9
Details on results:
Values were determined by a calculation method and by a HPLC method

Pow Calculation:

The Pow of the test item was calculated to be 7.9 x 104 (log Pow 4.9) using the Rekker calculation method.

pKa Values

No pKa values for acidic groups in the molecular structure of the test item in the logarithm range of 1 - 14 were calculated.

The pKa values in the logarithm range of 1 - 14 for basic groups in the molecular structure of the test item were calculated using the Perrin calculation method.  The results are given in the table below:

Basic
RRNH+(CH3) pKa6.7
RC6H4NH(CH3)2+ pKa3.7
RC6H4NH(CH3)2+ pKa3.1

HPLC Method:

pH 7

UPLC-UV chromatograms of the test item solution and corresponding blank are shown in Figure 4 and Figure 5, respectively. In the chromatogram of the test solution, one major test item peak was observed.

The results of the HPLC method are given in the table below.  The equation of the regression line was:

log k’ = 0.304 x log Pow – 0.654 (r = 0.998, n = 12).

Substance Retention time (min) log Pow Pow
tr,1 tr,2 mean
Formamide (t0) 0.617 0.614 0.616
1,4-Dichlorobenzene 2.072 2.061 3.4
Biphenyl 2.8 2.783 4
1,2,4-Trichlorobenzene 3.223 3.202 4.2
Dibenzyl 4.713 4.674 4.8
Triphenylamine 8.732 8.645 5.7
4,4’-DDT 12.691 12.552 6.5
Test item 3.237 3.229 3.233 4.2 1.6E104

pH 9

In the chromatogram of the test solution, one major test item peak was observed.

The results of the HPLC method are given in the table below. .  Figure 9 shows the calibration curve of the log k’ of the reference substances as function of log Pow . The equation of the regression line was:

log k’ = 0.455 ´ log Pow – 0.798 (r = 0.995, n = 12).

Substance Retention time (min) log Pow Pow
tr,1 tr,2 mean
Formamide (t0) 0.577 0.576 0.577
Benzylalcohol 0.827 0.825 1.1
Toluene 2.499 2.491 2.7
Bromobenzene 2.812 2.803 3
1,4-Dichlorobenzene 4.042 4.029 3.4
1,2,4-Trichlorobenzene 7.678 7.649 4.2
Dibenzyl 13.309 13.249 4.8
Test item 8.615 8.58 8.598 4.3 1.8´104
Conclusions:
The octanol-water partition coefficient of the test substance was determined to be 4.2 Log Pow at 35 °C and pH 7, under the conditions of the test.
Executive summary:

In this guideline (OECD 117) study, conducted with GLP certification, the octanol-water partition coefficient was found to be 4.2 at 35 °C and pH 7.

Endpoint:
partition coefficient
Type of information:
experimental study
Adequacy of study:
supporting study
Study period:
21 September 2006 - 17 October 2006
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.8 (Partition Coefficient - HPLC Method)
Version / remarks:
EC's Classification, Packaging & Labelling of Dangerous Substances in the European Union Part 2, Testing Methods, Jan97. Directive 92/69/EC (Annex V to Directive 67/548/EC)
GLP compliance:
yes (incl. QA statement)
Type of method:
HPLC method
Partition coefficient type:
octanol-water
Specific details on test material used for the study:
Product Name: LFC 2098
Special Hazards: None specified
Appearance: Sample observed to be a white powder (determined by Chilworth Technology Ltd).
Analytical method:
high-performance liquid chromatography
Type:
log Pow
Partition coefficient:
2.29
Temp.:
22 °C
pH:
4.72
Type:
log Pow
Partition coefficient:
2.28
Temp.:
22 °C
pH:
4.72
Details on results:
Mean log Pow result = 2.282

Sample Tr (s) Log K Log P
LFC 2098  656.4 0.819 2.29
LFC 2098  652.8 0.817 2.28
Mean 2.282
Conclusions:
Mean log Pow result = 2.282
Executive summary:

In this guideline (EU Method A.8) study, conducted with GLP certification, the partition coefficient of the test substance (EC 466 -080 -8) was shown to have log Pow = 2.282

Description of key information

Study conducted to recognised testing guidelines with GLP certification

Key value for chemical safety assessment

Log Kow (Log Pow):
4.2
at the temperature of:
35 °C

Additional information