Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
explosiveness, other
Type of information:
experimental study
Adequacy of study:
key study
Study period:
26Nov2001 to 11Dec2001
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2001
Report date:
2001

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
EU Method A.14 (Explosive properties)
GLP compliance:
yes (incl. QA statement)

Test material

Constituent 1
Chemical structure
Reference substance name:
2-[(4-aminophenyl)azo]-1,3-dimethyl-1H-imidazolium chloride
EC Number:
306-764-4
EC Name:
2-[(4-aminophenyl)azo]-1,3-dimethyl-1H-imidazolium chloride
Cas Number:
97404-02-9
Molecular formula:
C11H14N5.Cl
IUPAC Name:
2-[(1E)-2-(4-aminophenyl)diazen-1-yl]-1,3-dimethyl-2,3-dihydro-1H-imidazol-1-ium chloride
Test material form:
solid: particulate/powder
Details on test material:
See individual study reports for purity information and CofA where applicable

Results and discussion

Small-scale preliminary testsopen allclose all
Key result
Parameter:
thermal sensitivity - Koenen test: diameter of the orifice plate
Number of fragments:
0
Remarks on result:
not thermal sensitive if heated under defined confinement
Remarks:
no explosion observed with either 6mm or 2mm orifice plate
Key result
Parameter:
sensitiveness to impact: impact energy (J)
Remarks on result:
not sensitive to impact using an impact energy of 40 J
Key result
Parameter:
sensitiveness to friction: friction load (N)
Remarks on result:
not sensitive to friction using a friction load of 360 N

Applicant's summary and conclusion

Interpretation of results:
GHS criteria not met
Conclusions:
It was found that Fthe test item, is not an explosive Item according to the EC Directive 92/69/EEC, A.14.
Executive summary:

Testing was undertaken using methods described in EC Directive 92/69/EEC, A.14 for thermal, mechanical shock and mechanical friction sensitivity.

It was found that the test item is not an explosive Item according to the EC Directive 92/69/EEC, A.14