Physical & Chemical properties

Appearance / physical state / colour

Currently viewing:

Administrative data

Link to relevant study record(s)

Referenceopen allclose all

Endpoint:
appearance / physical state / colour
Type of information:
experimental study
Adequacy of study:
key study
Study period:
08 January 2018 to 02 February 2018
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
test procedure in accordance with generally accepted scientific standards and described in sufficient detail
Qualifier:
no guideline followed
Principles of method if other than guideline:
The physical state and appearance of the test material was reported as part of a study conducted in accordance with standardised guidelines and under GLP conditions to determine the skin corrosion potential of the test material.
GLP compliance:
yes
Physical state at 20°C and 1013 hPa:
liquid
Key result
Form:
liquid
Colour:
Blue
Substance type:
organic
Conclusions:
Under the conditions of this study, the test material was reported to be a blue liquid.
Executive summary:

The physical state and appearance of the test material was reported as part of a study conducted in accordance with standardised guidelines and under GLP conditions to determine the skin corrosion potential of the test material.

Under the conditions of this study, the test material was reported to be a blue liquid.

Endpoint:
appearance / physical state / colour
Type of information:
experimental study
Adequacy of study:
key study
Study period:
16 March 2018 to 11 April 2018
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
test procedure in accordance with generally accepted scientific standards and described in sufficient detail
Qualifier:
no guideline followed
Principles of method if other than guideline:
The physical state and appearance of the test material was reported as part of a study conducted in accordance with standardised guidelines and under GLP conditions to determine the physico-chemical properties of the test material.
GLP compliance:
yes
Physical state at 20°C and 1013 hPa:
solid
Key result
Form:
solid: particulate/powder
Colour:
Black
Substance type:
organic
Conclusions:
Under the conditions of this study, the test material was reported to be a black powder.
Executive summary:

The physical state and appearance of the test material was reported as part of a study conducted in accordance with standardised guidelines and under GLP conditions to determine the physico-chemical properties of the test material.

Under the conditions of this study, the test material was reported to be a black powder.

Description of key information

Eurlings (2018)

Under the conditions of this study, the test material was reported to be a blue liquid.

Volic (2018)

Under the conditions of this study, the test material was reported to be a black powder.

The pure substance is a powder but is only produced and marketed as a solution. Therefore the appearance of both forms of the substance have been included.

Key value for chemical safety assessment

Physical state at 20°C and 1013 hPa:
liquid

Additional information

Eurlings (2018)

The physical state and appearance of the test material was reported as part of a study conducted in accordance with standardised guidelines and under GLP conditions to determine the skin corrosion potential of the test material.

Under the conditions of this study, the test material was reported to be a blue liquid.

Volic (2018)

The physical state and appearance of the test material was reported as part of a study conducted in accordance with standardised guidelines and under GLP conditions to determine the physico-chemical properties of the test material.

Under the conditions of this study, the test material was reported to be a black powder.