Administrative data

Link to relevant study record(s)

Reference
Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2017
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
other: European Commission Guidance Document EUR 20268 ‘Determination of Particle Size Distribution, Fibre Length and Diameter Distribution of Chemical Substances’ (2002).
Deviations:
no
Principles of method if other than guideline:
test item was added to a 100 μm sieve fitted onto a receiver pan of known mass. A lid was then secured onto the sieve and the assembled apparatus placed on a sieve shaker for a period of approximately 30 minutes. The sieve shaker table, on which the sieve rests, had an inclination of 4.5°, a nominal rotation speed of 2.5 rpm and vibrated at approximately 300 oscillations/min with an approximately 4 mm amplitude and the percentage of test item with a particle size less than 100 μm calculated.
GLP compliance:
yes
Type of method:
sieving
Type of particle tested:
other: inhalable particle was determined
Type of distribution:
other: NS
Specific details on test material used for the study:
Identification: di-tert-butyl hydroquinone
CAS Number: 88-58-4
Appearance/Physical state: White solid
Batch: TS140610
Purity: 99.6%
Expiry date: 03 November 2018
Storage conditions: Room temperature, in the dark
Remarks on result:
other: The test item has been considered to be essentially non-inhalable
Remarks:
The test item has been considered to be essentially non-inhalable
Percentile:
other: NS
Remarks on result:
other: percentage of test item with a particle size less than 100 μm calculated.
Remarks:
particle size of less than 100 μm was determined to be 9.47%
Conclusions:
The percentage of test item having an inhalable particle size of less than 100 μm was determined to be 9.47%. The test item has been considered to be essentially non-inhalable
Executive summary:

The proportion of test item having an inhalable particle size of less than 100 μm was determined by a sieve method to be 9.47%. Particle size data was acquired, using a procedure designed to be compatible with the European Commission Technical Guidance Document EUR 20268 ‘Determination of Particle Size Distribution, Fibre Length and Diameter Distribution of Chemical Substances’ (2002).

Description of key information

Additional information

The proportion of test item having an inhalable particle size of less than 100 μm was determined by a sieve method to be 9.47%. Particle size data was acquired, using a procedure designed to be compatible with the European Commission Technical Guidance Document EUR 20268 ‘Determination of Particle Size Distribution, Fibre Length and Diameter Distribution of Chemical Substances’ (2002).