Physical & Chemical properties

Auto flammability

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
auto-ignition temperature (liquids)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
From 12 December 2016 to 13 December 2016
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.15 (Auto-Ignition Temperature (Liquids and Gases))
Version / remarks:
2008
Deviations:
no
Qualifier:
according to guideline
Guideline:
DIN 51794 (Testing of mineral oil hydrocarbons - Determination of ignition temperature)
Version / remarks:
2003
Deviations:
no
Qualifier:
according to guideline
Guideline:
IEC 60079-4 (Electrical apparatus for explosive gas atmospheres. Part 4: Method of test for ignition temperature)
Version / remarks:
1975
Deviations:
no
GLP compliance:
yes
Key result
Auto-ignition temperature:
350 °C
Atm. press.:
>= 1 023.5 - <= 1 025.3 hPa

Table: Results of the auto-ignition temperature measurements

 

Test

Volume

[μL]

Auto-ignition
temperature

[°C]

Ignition delay

[s]

Colour of the flame

Lowest auto-ignition

Temperature

[°C]

 

 

 

 

 

 

1

40

365

3

Orange/blue

359

 

70

359

4

Orange/blue

 

 

140

362

3

Orange/blue

 

 

 

 

 

 

 

2

55

364

3

Orange

353

 

100

353

4

Orange/blue

 

 

200

360

3

Orange

 

 

 

 

 

 

 

3

85

363

3

Orange/blue

354

 

120

354

3

Orange/blue

 

 

180

355

5

Orange/blue

 

 

 

 

 

 

 

 

Conclusions:
The auto-ignition temperature at 1024-1025 hPa was determined to be 350°C.
Executive summary:

The auto-ignition temperature of the substance at 1024 -1025 hPa was determined to be 350°C in a GLP study according to EC A.15, DIN 51794 and IEC 79-4.

Description of key information

The auto-ignition temperature of the substance at 1024 -1025 hPa was determined to be 350 °C in a GLP study according to EC A.15, DIN 51794 and IEC 79-4.

Key value for chemical safety assessment

Autoflammability / Self-ignition temperature at 101 325 Pa:
350 °C

Additional information