Physical & Chemical properties

Viscosity

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
viscosity
Type of information:
experimental study
Adequacy of study:
key study
Study period:
from 2016-06-10 to 2016-10-06
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
CIPAC MT 192 (Viscosity of liquids by rotational viscometry)
Deviations:
no
Qualifier:
according to guideline
Guideline:
OECD Test Guideline 114 (Viscosity of Liquids)
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Type of method:
rotational viscometer (dynamic)
Standard covering the apparatus used:
CIPAC MT192 - ISO 3219
Specific details on test material used for the study:
SOURCE OF TEST MATERIAL
Test item: MCPP-P 2-EHE
Batch No.: CHP0001
Purity: 96.1%
Expiry date: 2017-05-04
Key result
Temp.:
20°C
Parameter:
dynamic viscosity (in mPa s)
Value:
24.83
Remarks on result:
other: mPas
Temp.:
20°C
Parameter:
kinematic viscosity (in mm²/s)
Value:
23.79
Remarks on result:
other: calculated, [cSt]
Key result
Temp.:
40°C
Parameter:
dynamic viscosity (in mPa s)
Value:
10.45
Remarks on result:
other: mPas
Temp.:
40°C
Parameter:
kinematic viscosity (in mm²/s)
Value:
10.17
Remarks on result:
other: calculated, [cSt]

Table 1: Dynamic Viscosity of the test item at 20 °C

Test time (storage condition)

Test item No.

Viscosity [mPa*s]a)

181 rpm

90.5 rpm

45.2 rpm

22.6 rpm

11.3 rpm

5.6 rpm

Start

1

24.18

24.24

24.72

25.92

26.88

23.04

a) Mean of two measurements

Table 2: Kinematic Viscosity of the test item at 20 °C (calculated)

Test time (storage condition)

Test item No.

Viscosity [cSt]a)

181 rpm

90.5 rpm

45.2 rpm

22.6 rpm

11.3 rpm

5.6 rpm

Start

1

23.16

23.22

23.68

24.83

25.75

22.07

a) Mean of two measurements (calculations)

Table 3: Dynamic Viscosity of the test item at 40 °C

Test time (storage condition)

Test item No.

Viscosity [mPa*s]a)

181 rpm

90.5 rpm

45.2 rpm

22.6 rpm

11.3 rpm

5.6 rpm

Start

1

10.02

10.44

10.56

10.56

11.52

9.60

a) Mean of two measurements

Table 4: Kinematic Viscosity of the test item at 40 °C (calculated)

Test time (storage condition)

Test item No.

Viscosity [cSt]a)

181 rpm

90.5 rpm

45.2 rpm

22.6 rpm

11.3 rpm

5.6 rpm

Start

1

9.75

10.16

10.27

10.27

11.21

9.34

a) Mean of two measurements (calculations)

Conclusions:
The dynamic viscosity of the test substance at 20 °C was 24.83 mPas and the kinematic viscosity at 20 °C was 23.79 cSt. At 40 °C the dynamic viscosity was 10.45 mPas and the kinematic viscosity at 40 °C was 10.17 cSt.
Executive summary:

A study was conducted according to CIPC MT 192 and OECD TG 114 to determine the dynamic viscosity of the test item using the dynamic rotational viscometer method. The dynamic viscosity was determined to be 24.83 mPa*s at 20 °C and 10.45 mPa*s at 40 °C, respectively. The kinematic viscosity at both temperatures was calculated to be: 23.79 cSt at 20 °C and 10.17 cSt at 40 °C. No observations were made which cause doubt on the validity of the outcome of the study.

Description of key information

The dynamic viscosity of the test substance at 20 °C was 24.83 mPas and the kinematic viscosity at 20 °C was 23.79 cSt. At 40 °C the dynamic viscosity was 10.45 mPas and the kinematic viscosity at 40 °C was 10.17 cSt.

Key value for chemical safety assessment

Viscosity:
24.83 mPa · s (dynamic)
at the temperature of:
20 °C

Additional information

A study was conducted according to CIPC MT 192 and OECD TG 114 to determine the dynamic viscosity of the test item using the dynamic rotational viscometer method [Mo55016, 2016]. The dynamic viscosity was determined to be 24.83 mPa*s at 20 °C and 10.45 mPa*s at 40 °C, respectively. The kinematic viscosity at both temperatures was calculated to be: 23.79 cSt at 20 °C and 10.17 cSt at 40 °C. No observations were made which cause doubt on the validity of the outcome of the study.