Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Flammability

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
4 October 2010 to 6 December 2010
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: GLP Compliant, guideline study, available as unpublished report, acceptable without restrictions.
Qualifier:
equivalent or similar to guideline
Guideline:
other: EC No 1272/2008 Method N.1 of the United Nations Recommendations on the Transport of Dangerous Goods, Manual of Tests and Criteria, fifth revised edition 2009
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Test procedure:
burning rate test: preliminary screening test
Remarks on result:
other: Pile failed to ignite during the two minutes that the Bunsen flame was applied.

Pile failed to ignite during the two minutes that the Bunsen flame was applied.

Interpretation of results:
non flammable
Remarks:
Migrated information
Conclusions:
Diammonium hexachloropalladate is not classified as a readily combustible solid under Division 4.1 as it failed to ignite in the preliminary screening test.
Executive summary:

This is a GLP compliant, guideline study considered suitable for use as the key study for this endpoint. Diammonium hexachloropalladate is not classified as a readily combustible solid under Division 4.1 as it failed to ignite in the preliminary screening test.

Description of key information

Diammonium hexachloropalladate is not classified as a readily combustible solid under Division 4.1 as it failed to ignite in the preliminary screening test.

Key value for chemical safety assessment

Flammability:
non flammable

Additional information

The result is taken from a GLP-compliant, guideline study considered suitable for use as the key study for this endpoint (Tremain and Atwal 2011). Diammonium hexachloropalladate is not classified as a readily combustible solid under Division 4.1 as it failed to ignite in the preliminary screening test.

Justification for classification or non-classification

Based on results from a GLP-compliant, guideline study diammonium hexachloropalladate is not classified as a readily combustible solid under Division 4.1.