Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Density

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
relative density
Type of information:
experimental study
Adequacy of study:
key study
Study period:
02-03-2015 to 27-05-2015
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: Guideline study performed under GLP. All relevant validity criteria were met.
Qualifier:
according to guideline
Guideline:
EU Method A.3 (Relative Density)
Deviations:
no
Qualifier:
according to guideline
Guideline:
OECD Guideline 109 (Density of Liquids and Solids)
Deviations:
no
Qualifier:
according to guideline
Guideline:
EPA OPPTS 830.7300 (Density / Relative Density / Bulk Density)
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Remarks:
inspected March 2013 ; signature: May 2013
Type of method:
pycnometer method
Type:
relative density
Density:
0.972 other: dimensionless
Temp.:
20 °C
Remarks on result:
other: mean relative density (n=2)
Type:
density
Density:
0.97 g/cm³
Temp.:
20 °C
Remarks on result:
other: mean density (n=2)

Table 1. Determination of the density of the test item

 

Test 1

Test 2

Mean

 

 

 

 

Mass empty pycnometer (A)

30.4746 g

30.4745 g

30.4746 g

Mass pycnometer with water (B)

40.1145 g

40.1114 g

 

Volume of the pycnometer

9.6573 cm3

9.6543 cm3

9.6558 cm3

 

 

 

 

Mass pycnometer with test item (C)

39.8631 g

39.8638 g

 

Density

0.9723 g/cm3

0.9724 g/cm3

0.972 g/cm3

Conclusions:
The relative density of the test item was determined to be 0.972 at 20 °C using the pycnometer method.
Executive summary:

The relative density was determined using EU Method A.3 using the pycnometer method under GLP. The mean density (n=2) of the test item was determined to be 972 kg/m^3 at 20°C. The relative density was 0.972.

Description of key information

Relative Density: 0.972 at 20°C, EU Method A.3 pycnometer method, 2015

Key value for chemical safety assessment

Relative density at 20C:
0.972

Additional information

Key study : EU Method A.3, 2015 : The relative density was determined using EU Method A.3 using the pycnometer method under GLP. The mean density (n=2) of the test item was determined to be 972 kg/m^3 at 20°C. The relative density was 0.972.