Physical & Chemical properties

Particle size distribution (Granulometry)

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
Oct 2012
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
no guideline followed
Principles of method if other than guideline:
The size distribution of the suspended particles was determined by laser diffraction method.
GLP compliance:
no
Other quality assurance:
ISO/IEC 17025 (General requirements for the competence of testing and calibration laboratories)
Type of method:
Laser scattering/diffraction
Type of distribution:
volumetric distribution
Key result
Percentile:
D10
Mean:
86.83 µm
St. dev.:
0
Key result
Percentile:
D50
Mean:
260.5 µm
St. dev.:
0
Key result
Percentile:
D90
Mean:
506.6 µm
St. dev.:
0
Conclusions:
d10 d50 d90
DIACETYL THYMIDINE 86.83 μm 260.5 μm 506.6 μm

Description of key information

                                                        d10              d50               d90

DIACETYL THYMIDINE       86.83 μm       260.5 μm       506.6 μm

Additional information