Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
Testing was conducted between 5th of January 2011 and 14 of April 2011.
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: Study conducted to GLP and in compliance with agreed protocols, with no or minor deviations from standard test guidelines and/or minor methodological deficiencies, which do no effect the quality of the relevant results.
Cross-referenceopen allclose all
Reason / purpose for cross-reference:
reference to same study
Reason / purpose for cross-reference:
reference to other study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2011
Report date:
2011

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
EU Method A.10 (Flammability (Solids))
Deviations:
no
GLP compliance:
yes
Remarks:
Date of GLP inspection: 2010-07-20

Test material

Constituent 1
Reference substance name:
Bismuth Copper Cement
IUPAC Name:
Bismuth Copper Cement
Details on test material:

Description: dark brown solid
Date received: 01. Nov 2010
Storage conditions: room temperature, in the dark

Results and discussion

Pyrophoric solids
Test procedure:
ignition time on contact with air
Remarks:
Ignition on contact with air refers to either Pyrophoric solids or Pyrophoric liquids depending on physical state (migrated information).
Remarks on result:
no ignition on contact with air (not further specified)
Remarks:
corresponding to 'no' in migrated source record.
Pyrophoric liquids
Test procedure:
ignition time on contact with air
Remarks:
Ignition on contact with air refers to either Pyrophoric solids or Pyrophoric liquids depending on physical state (migrated information).
Remarks on result:
no ignition on contact with air (not further specified)
Remarks:
corresponding to 'no' in migrated source record.

Any other information on results incl. tables

Result

The pile failed to ignite during the 2 minutes that the Bunsen burner flame was applied.

Applicant's summary and conclusion

Interpretation of results:
non flammable
Remarks:
Migrated information The test material has been determined to be not highly flammable as it failed to ignite in the preliminary screening test.