Registration Dossier
Registration Dossier
Data platform availability banner - registered substances factsheets
Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.
The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.
Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: 700-144-0 | CAS number: 13115-71-4
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data
Flammability
Administrative data
Link to relevant study record(s)
- Endpoint:
- flammable solids
- Type of information:
- experimental study
- Adequacy of study:
- key study
- Study period:
- 2008-07-14
- Reliability:
- 1 (reliable without restriction)
- Rationale for reliability incl. deficiencies:
- guideline study
- Qualifier:
- according to guideline
- Guideline:
- EU Method A.10 (Flammability (Solids))
- Deviations:
- no
- GLP compliance:
- yes (incl. QA statement)
- Remarks:
- Hessisches Ministerium für Umwelt, ländlichen Raum und Verbraucherschutz, Wiesbaden, Germany
- Key result
- Test procedure:
- burning rate test: preliminary screening test
- Remarks on result:
- substance does not ignite and propagate combustion either by burning with flame or smouldering along 200 mm of the powder train within the 2 minutes test period
- Remarks:
- the test item melted at contact with flame
- Interpretation of results:
- not classified based on GHS criteria
- Remarks:
- Migrated information
- Conclusions:
- The test item is not a highly flammable solid in the sense of the European Commission Regulation (EC) No. 440/2008, Method A.10. and is not a flammable solid in the sense of the classification criteria as laid down in Regulation (EC) No. 1272/2008 (CLP Regulation).
- Endpoint:
- substances / mixtures which in contact with water emit flammable gases
- Data waiving:
- study scientifically not necessary / other information available
- Justification for data waiving:
- the study does not need to be conducted because the experience in production or handling shows that the substance does not react with water, e.g. the substance is manufactured with water or washed with water
- Endpoint:
- pyrophoric solids
- Data waiving:
- study scientifically not necessary / other information available
- Justification for data waiving:
- the study does not need to be conducted because the substance is known to be stable in contact with air at room temperature for prolonged periods of time (days) and hence, the classification procedure does not need to be applied
- Endpoint:
- self-heating substances / mixtures
- Data waiving:
- study scientifically not necessary / other information available
- Justification for data waiving:
- other:
- Justification for type of information:
- JUSTIFICATION FOR DATA WAIVING
The classification procedure for self-heating substances or mixtures need not be applied if the results of a screening test can be adequately correlated with the classification test and an appropriate safety margin is applied. An example of screening tests is the Grewer Oven test (VDI guideline 2263, part 1, 1990, Test methods for the Determination of the Safety Characteristics of Dusts).
The Grewer Oven test performed with the substance results in no exothermic effects up to 430 °C (report no. 2008-0150-DGS). Therefore, the substance is not self-heating on the basis of the screening test and the classification test N.4 in Part III, subsection 33.3.1.6 of the UN-MTC, need not be performed. - Reason / purpose for cross-reference:
- data waiving: supporting information
Referenceopen allclose all
The substance could not be ignited by flame during the preliminary test.
A main test was therefore not necessary.
Description of key information
non flammable
not pyrophoric
no flammability on contact with water
not self-heating
Key value for chemical safety assessment
- Flammability:
- not classified
Additional information
No ignition in the preliminary burning rate test (EU Method A.10).
Based on experience in handling and use pyrophoricity and flammability on contact with water are not to be expected.
The substance showed no self-heating behaviour (no exothermic effects up to 430 °C) in a Grewer Oven test.
Justification for classification or non-classification
The available data on flammability of the test substance do not meet the criteria for classification according to Regulation (EC) 1272/2008, and are therefore conclusive but not sufficient for classification:
No ignition in the preliminary burning rate test (EU Method A.10).
Based on experience in handling and use pyrophoricity and flammability on contact with water are not to be expected.
The substance showed no self-heating behaviour (no exothermic effects up to 430 °C) in a Grewer Oven test.
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.