Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Density

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
density, other
Remarks:
density
Type of information:
experimental study
Adequacy of study:
key study
Study period:
24 February 2017
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: Only a 2 page study summary, though the critical information for this endpoint is included.
Remarks:
Conducted according to GLP
Qualifier:
according to guideline
Guideline:
OECD Guideline 109 (Density of Liquids and Solids)
Deviations:
no
Qualifier:
according to guideline
Guideline:
EU Method A.3 (Relative Density)
Deviations:
no
GLP compliance:
yes
Other quality assurance:
ISO/IEC 17025 (General requirements for the competence of testing and calibration laboratories)
Type of method:
air comparison pycnometer (for solids)
Specific details on test material used for the study:
SOURCE OF TEST MATERIAL
- Source and lot/batch No.of test material: 2017/02
- Expiration date of the lot/batch: No data
- Purity test date: No data

STABILITY AND STORAGE CONDITIONS OF TEST MATERIAL
- Storage condition of test material: No data
- Stability under test conditions: No data
- Solubility and stability of the test substance in the solvent/vehicle: No data
- Reactivity of the test substance with the solvent/vehicle of the cell culture medium: No data

TREATMENT OF TEST MATERIAL PRIOR TO TESTING
- Treatment of test material prior to testing: No data
- Final dilution of a dissolved solid, stock liquid or gel: No data
- Final preparation of a solid: No data
Dynamic viscosity of test material:
No data
Key result
Type:
density
Density:
2.705 g/cm³
Temp.:
20 °C

 Test number    1  2
 Mass/g    2.2683  2.1284
 Temperature/°C  Run  19.98  20.03
 Volume/cm3  0.8358  0.7894
   2  0.8353  0.7891
   3  0.8362  0.7888
   4  0.8373  0.7899
   5  0.8364  0.7896
 Average volume/cm3    0.8362  0.7894
 Density/gcm-3    2.7126  2.6964
Conclusions:
The density of tetraammineplatinum(II) hydrogen carbonate at 20 °C was determined to be 2.705 g/cm3.

Executive summary:

In a guideline study, conducted to GLP, the density of tetraammineplatinum(II) hydrogen carbonate was determined by the pycnometer method to be 2.705 g/cm3 at a temperature of 20 °C.

Description of key information

The density of tetraammineplatinum(II) hydrogen carbonate at 20 °C was determined to be 2.705 g/cm3 (Mekelburger, 2017a).

Key value for chemical safety assessment

Relative density at 20C:
2.705

Additional information