Endpoint:
flammability
Remarks:
Pyrophoric liquids/solids (migrated from section 'Flammability')
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: GLP Compliant, guideline study, available as unpublished report, acceptable without restrictions

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2011
Report date:
2011

Materials and methods

Test guideline
Qualifier:
equivalent or similar to guideline
Guideline:
other: EC No 1272/2008 Method N.1 of the United Nations Recommendations on the Transport of Dangerous Goods, Manual of Tests and Criteria, fifth revised edition 2009
Deviations:
yes
Remarks:
Limited availability of the test item it was not possible to completely fill the mould to a length of 250mm as recommended by the test guideline. this was concluded not to impact on the validity of the determination as the test item pile failed to ignite
GLP compliance:
yes (incl. QA statement)

Test material

Constituent 1
Chemical structure
Reference substance name:
Palladium dichloride
EC Number:
231-596-2
EC Name:
Palladium dichloride
Cas Number:
7647-10-1
Molecular formula:
Cl2Pd
IUPAC Name:
palladium dichloride
Details on test material:
Dark brownpowder , purity 59.701% (as Pd), Batch Number 15616 stored at room temperature in the dark

Results and discussion

Flammable solids
Test procedure:
burning rate test: preliminary screening test
Remarks on result:
other: Pile failed to ignite during the two minutes that the Bunsen flame was applied..

Any other information on results incl. tables

Pile failed to ignite during the two minutes that the Bunsen flame was applied..

Applicant's summary and conclusion

Interpretation of results:
non flammable
Remarks:
Migrated information
Conclusions:
Palladium dichoride is not classified as a readily combustible solid under Division 4.1 as it failed to ignite in the preliminary screening test.
Executive summary: