Registration Dossier

Physical & Chemical properties

Vapour pressure

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
vapour pressure
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: According to international guideline(s), GLP-compliant, performed in recognized contract research organization, no restrictions, fully adequate for assessment.
Qualifier:
according to
Guideline:
OECD Guideline 104 (Vapour Pressure Curve)
Deviations:
no
Qualifier:
according to
Guideline:
EU Method A.4 (Vapour Pressure)
Deviations:
no
GLP compliance:
yes (incl. certificate)
Type of method:
effusion method: vapour pressure balance
Key result
Temp.:
25 °C
Vapour pressure:
1.3 other: x 10E-3 Pa

Full results of the two runs:

 

Run 1

Run 2

 

 

 

Correlation (r):

-0.9966

-0.9960

Slope:

-2973

-3175

Intercept:

 7.108

7.714

Vp (Pa) at 25°C:.

1.4 x 10 -3

 1.2 x 10-3

 

Description of key information

1.3 x 10E-3 Pa at 25°C (OECD 104, EU A.4)

Key value for chemical safety assessment

Vapour pressure:
0.001 Pa
at the temperature of:
25 °C

Additional information