Registration Dossier

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Description of key information

75 °C at 1013 hPa

Key value for chemical safety assessment

Flash point at 101 325 Pa:
75 °C

Additional information

The flash point of the test item was determined according to ASTM D 7094-04 by the closed cup method.

The flash point of the test item is 75 °C at 101.3 kPa.

The flash point of the test item was also determined according to DIN-EN-ISO 2719 / ASTM D93-07 by a Pensky Martens Closed Cup apparatus. The flash point of the test item is 77 °C at 1013 hPa.

The lowest value of these determinations (75 °C) was taken as the flash point of the submission substance as a conservative estimate.

The determined flash point values do not lead to classification as a flammable liquid according to GHS/CLP (Regulation (EC) 2008/1272).