Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
flammability
Remarks:
Pyrophoric liquids/solids (migrated from section 'Flammability')
Type of information:
experimental study
Adequacy of study:
key study
Study period:
January 22, 1991
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: GLP study.

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
1991
Report date:
1991

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
EU Method A.13 (Pyrophoric Properties of Solids and Liquids)
GLP compliance:
yes

Test material

Constituent 1
Chemical structure
Reference substance name:
α-trimethylsilanyl-ω-trimethylsiloxypoly[oxy(methyl-3-(2-(2-methoxypropoxy)propoxy)propylsilanediyl]-co-oxy(dimethylsilane))
EC Number:
406-420-4
EC Name:
α-trimethylsilanyl-ω-trimethylsiloxypoly[oxy(methyl-3-(2-(2-methoxypropoxy)propoxy)propylsilanediyl]-co-oxy(dimethylsilane))
Cas Number:
69430-40-6
Molecular formula:
Unspecified example: C18.3H46.8O5.8Si4.1
IUPAC Name:
2,2,4,4,6,12,15-heptamethyl-6-[(trimethylsilyl)oxy]-3,5,10,13,16-pentaoxa-2,4,6-trisilaheptadecane
Details on test material:
Identification: DC 5067
Description: Clear, light brown liquid
Lot Number: AB 090122
Purity: >99%
Storage conditions: In the original container at room temperature in the dark
Stability under storage conditions: Stab1e
Expiry date: December 1, 1991

Results and discussion

Pyrophoric solids
Test procedure:
ignition time on contact with air
Remarks:
Ignition on contact with air refers to either Pyrophoric solids or Pyrophoric liquids depending on physical state (migrated information).
Remarks on result:
no ignition on contact with air (not further specified)
Remarks:
corresponding to 'no' in migrated source record.
Pyrophoric liquids
Test procedure:
ignition time on contact with air
Remarks:
Ignition on contact with air refers to either Pyrophoric solids or Pyrophoric liquids depending on physical state (migrated information).
Remarks on result:
no ignition on contact with air (not further specified)
Remarks:
corresponding to 'no' in migrated source record.

Any other information on results incl. tables

No ignition of the test substance was observed during the performance of the test. From this it was concluded that DC 5067 is not highly flammable at 20°C, under the conditions of the test.

Applicant's summary and conclusion

Interpretation of results:
non flammable
Remarks:
Migrated information
Conclusions:
No ignition of the test substance was observed during the performance of the test. From this it was concluded that DC 5067 is not highly flammable
at 20°C, under the conditions of the test.
Executive summary:

The determination of the flammability of DC 5067 was performed in accordance with EEC-Directive A-13: "Flammability (solids and liquids)". No ignition of the test substance at room temperature was observed. In conclusion, DC 5067 has not to be classified 'highly flammable" according to the criteria in method A.13 of directive 84/449/EEC.