Diss Factsheets

Physical & Chemical properties

Flammability

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
24 August 2018
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.10 (Flammability (Solids))
Version / remarks:
2008
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Key result
Test procedure:
burning rate test: preliminary screening test
Remarks on result:
substance does not ignite and propagate combustion either by burning with flame or smouldering along 200 mm of the powder train within the 2 minutes test period

Preliminary Test

- In the preliminary test the test material could not be ignited.

- Based on the results of the preliminary test, no main test was performed.

Interpretation of results:
other: Not classified in accordance with EU criteria
Conclusions:
Under the conditions of this study, the test material could not be ignited and therefore is considered not to be highly flammable.
Executive summary:

The flammability of the test material was investigated in accordance with the standardised guideline EU Method A.10, under GLP conditions.

In the preliminary test the test material could not be ignited. Based on the results of the preliminary test, no main test was performed.

Under the conditions of this study, the test material could not be ignited and therefore is considered not to be highly flammable.

Description of key information

Flammability (solids)

Under the conditions of the study, the test material could not be ignited and therefore is considered not to be highly flammable.

Key value for chemical safety assessment

Flammability:
not classified

Additional information

Flammability (solids)

The flammability of the test material was investigated in accordance with the standardised guideline EU Method A.10, under GLP conditions. The study was awarded a reliability score of 1 in accordance with the criteria set forth by Klimisch et al. (1997).

In the preliminary test the test material could not be ignited. Based on the results of the preliminary test, no main test was performed.

Under the conditions of this study, the test material could not be ignited and therefore is considered not to be highly flammable.

Flammability (pyrophoricity)

In accordance with Section 1 of REACH Annex XI, the study does not need to be performed as based on chemical structure and experience in use pyrophoricity is not to be expected and hence testing does not appear scientifically necessary.

Flammability (contact with water)

In accordance with Section 1 of REACH Annex XI, the study does not need to be performed as based on chemical structure and experience in use water reactivity is not to be expected and hence testing does not appear scientifically necessary.

Justification for classification or non-classification

In accordance with the criteria for classification as defined in Annex I, Regulation (EC) No 1272/2008, the substance does not require classification with respect to flammability.