Administrative data

Endpoint:
pH
Type of information:
experimental study
Adequacy of study:
supporting study
Study period:
2018-02-22
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
comparable to guideline study with acceptable restrictions

Data source

Reference
Reference Type:
other company data
Title:
Unnamed
Year:
2018
Report date:
2018

Materials and methods

Test guideline
Qualifier:
equivalent or similar to guideline
Guideline:
OECD Guideline 122 (Determination of pH, Acidity and Alkalinity)
GLP compliance:
no

Test material

Constituent 1
Chemical structure
Reference substance name:
Phenylphosphonic dichloride
EC Number:
212-534-3
EC Name:
Phenylphosphonic dichloride
Cas Number:
824-72-6
Molecular formula:
C6H5Cl2OP
IUPAC Name:
phenylphosphonic dichloride
Test material form:
liquid

Reagents

Reagent:
water

Results and discussion

pH value
Key result
pH value:
0.73
Temp.:
20 °C
Concentration:
1 vol%

Applicant's summary and conclusion

Conclusions:
A pH analysis according to OECD / OCDE test guidline 122 was performed. The recorded pH-value after 10 minutes of immersion of the electrode was 0.73.
Executive summary: