Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Flammability

Currently viewing:

Administrative data

Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
1995-09-04 until 1995-11-27
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: Guideline-conform study under GLP without deviations.
Cross-reference
Reason / purpose for cross-reference:
reference to other study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
1995
Report date:
1995

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
EU Method A.10 (Flammability (Solids))
Deviations:
no
GLP compliance:
yes
Remarks:
This study was performed in compliance with Good Laboratory Practice (GLP) in Switzerland, Procedures and Principles, March 1986,

Test material

Constituent 1
Chemical structure
Reference substance name:
-
EC Number:
431-060-1
EC Name:
-
Cas Number:
153719-38-1
Molecular formula:
Hill formula: C4H8N4O3 CAS formula: C4H8N4O3
IUPAC Name:
3-methyl-N-nitro-3,6-dihydro-2H-1,3,5-oxadiazin-4-amine
Details on test material:
- Name of test material (as cited in study report): CA 2343 A (Intermediate of CGA 293343)
- Substance type: mono-constituent organic substance
- Physical state: solid, fine, white powder
- Analytical purity: 96.7 %
- Impurities (identity and concentrations): no data
- Purity test date: no data
- Lot/batch No.: P.503005
- Expiration date of the lot/batch: Date of reanalysis: December 1996
- Stability under test conditions: not reported
- Storage condition of test material: 0 - 5 °C

Results and discussion

Flammable gases (Lower and upper explosion limit)open allclose all
Parameter:
lower explosion limit
Value:
0 % (not further specified)
Parameter:
upper explosion limit
Value:
0 % (not further specified)
Flammable solids
Test procedure:
burning time (test type not further specified)
Remarks:
or specified in description of method (migrated information)
Burning time:
> 300 s
Pyrophoric solids
Test procedure:
ignition time on contact with air
Remarks:
Ignition on contact with air refers to either Pyrophoric solids or Pyrophoric liquids depending on physical state (migrated information).
Remarks on result:
no ignition on contact with air (not further specified)
Remarks:
corresponding to 'no' in migrated source record.
Pyrophoric liquids
Test procedure:
ignition time on contact with air
Remarks:
Ignition on contact with air refers to either Pyrophoric solids or Pyrophoric liquids depending on physical state (migrated information).
Remarks on result:
no ignition on contact with air (not further specified)
Remarks:
corresponding to 'no' in migrated source record.

Any other information on results incl. tables

Main test: Burning time to 100 mm

Comment in study report: "Cannot be done", no burning times stated in the report

Test on flammability in contact with water (cross reference to the study of the Institute of Safety & Security 1999):

Three test runs, over a duration of 7 hours each, were conducted. The observation recorded is always "no gas evolution". Therefore the total outcome of this study is that test substance CA 2343 oxadiazinamine is not highly flammable. Lower and upper explosion limits for gas therefore are not applicable for characterizing the flammability of the test item.

Applicant's summary and conclusion

Interpretation of results:
other: not highly flammable
Conclusions:
The substance is not considered highly flammable.
Executive summary:

The purpose of this study was to determine the flammability of the solid test substance CA 2343 (oxadiazinamine). The study followed the protocol acc. to EU Method A.10 (Flammability (Solids)). As the outcome of the study, the substance s not considered highly flammable.