Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
melting point/freezing point
Type of information:
experimental study
Adequacy of study:
key study
Study period:
04-May to 16-May-2006
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Cross-reference
Reason / purpose for cross-reference:
reference to same study
Reference
Endpoint:
appearance / physical state / colour
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
study well documented, meets generally accepted scientific principles, acceptable for assessment
Remarks:
The appearance of the test item is described in a reliable study report on the physical-chemical prope rties of the substance. Since no guideline was followed and no details on the methods are given, the description is considered as reliable with restrictions.
Reason / purpose for cross-reference:
reference to same study
Principles of method if other than guideline:
Visual inspection
GLP compliance:
no
Physical state at 20°C and 1013 hPa:
liquid
Substance type:
organic
Conclusions:
The substance is a liquid.

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2006
Report date:
2006

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to guideline
Guideline:
OECD Guideline 102 (Melting point / Melting Range)
Qualifier:
according to guideline
Guideline:
EU Method A.1 (Melting / Freezing Temperature)
GLP compliance:
yes (incl. QA statement)
Remarks:
Hess. Ministerium fur Umwelt, ländlichen Raum und Verbraucherschutz, Wiesbaden, Germany
Type of method:
differential scanning calorimetry

Test material

Reference
Name:
Unnamed
Type:
Constituent
Test material form:
liquid

Results and discussion

Melting / freezing point
Melting / freezing pt.:
2 °C
Atm. press.:
1 013 hPa

Applicant's summary and conclusion

Conclusions:
The test item melted at 2 °C at 1013 hPa according to test method OECD 102.