Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Particle size distribution (Granulometry)

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
25 Jul - 06 Aug 2020
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
study well documented, meets generally accepted scientific principles, acceptable for assessment
Qualifier:
no guideline followed
Principles of method if other than guideline:
- Principle of test: dynamic image analysis using pulsed light source
- Short description of test conditions: dispersing method, pressure 1 bar, vacuum 11 mbar
- Parameters analysed / observed: volumetric particle size distribution
GLP compliance:
no
Type of method:
other: Dynamic image analysis
Type of particle tested:
primary particle
Type of distribution:
volumetric distribution
Mass median aerodynamic diameter:
221.33 µm
Remarks on result:
other: standard deviation +/- 24.47 µm (11.05%)
Percentile:
D10
Mean:
92.21 µm
St. dev.:
8.28
Percentile:
D50
Mean:
207.47 µm
St. dev.:
11.96
Percentile:
D90
Mean:
391.03 µm
St. dev.:
78.39

SMD = 138.60 µm

VMD = 221.23 µm

Description of key information

D10: 92.21 µm

D50: 207.47 µm

D90: 391.03 µm

(Dynamic image analysis)

Additional information