Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Environmental fate & pathways

Biodegradation in water: screening tests

Administrative data

Endpoint:
biodegradation in water: ready biodegradability
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
guideline study with acceptable restrictions

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2018
Report date:
2018

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
OECD Guideline 301 B (Ready Biodegradability: CO2 Evolution Test)
Version / remarks:
1992
Deviations:
yes
Remarks:
Temperature range was 19.5 – 21.2 °C instead of 20.0 – 24.0 °C. As degradation of the positive control was in the normal range, this is considered as uncritical concerning the outcome of the study.
GLP compliance:
yes (incl. QA statement)
Remarks:
Landesamt für Umwelt, Wasserwirtschaft und Gewerbeaufsicht, Rheinland-Pfalz, Mainz, Germany

Test material

Constituent 1
Chemical structure
Reference substance name:
{[4-({dimethyl[3-(prop-2-enamido)propyl]azaniumyl}methyl)phenyl]methyl}dimethyl[3-(prop-2-enamido)propyl]azanium dichloride
EC Number:
812-548-5
Cas Number:
1621424-03-0
Molecular formula:
C24H40Cl2N4O2
IUPAC Name:
{[4-({dimethyl[3-(prop-2-enamido)propyl]azaniumyl}methyl)phenyl]methyl}dimethyl[3-(prop-2-enamido)propyl]azanium dichloride

Study design

Oxygen conditions:
aerobic
Inoculum or test system:
activated sludge, domestic (adaptation not specified)
Details on inoculum:
- Source of inoculum/activated sludge: activation basin of the ESN (Stadtentsorgung Neustadt) sewage treatment plant, NW-Lachen-Speyerdorf, Germany (12. Jan. 2018)
- Preparation of inoculum for exposure: filtrated, washed with test medium (2x) and re-suspended in test medium, aerated until use
- Concentration of sludge: 25.0 mg dry matter/L (4900 mg of suspended solids/L)
- Initial cell/biomass concentration: approx. 10^7 - 10^8 cells/L
Duration of test (contact time):
28 d
Initial test substance concentration
Initial conc.:
20 mg/L
Based on:
DOC
Parameter followed for biodegradation estimation
Parameter followed for biodegradation estimation:
CO2 evolution
Details on study design:
TEST CONDITIONS
- Composition of medium: according to OECD 301
- Test temperature: 19.5 - 21.2°C
- pH: 7.1 - 7.7
- pH adjusted: no
- Suspended solids concentration: 25 mg/L

TEST SYSTEM
- Culturing apparatus: 2000 mL-SCHOTT-flasks as test vessels, 100 mL scrubber flasks as absorbent vessels
- Number of culture flasks/concentration: 2
- Method used to create aerobic conditions: all flasks were aerated with purified, CO2-free, moistened air to purge the system of CO2
- Measuring equipment: IC measurement using the carbon analyser TOC multi N/C 2100S, Analytik Jena, Germany
- Details of trap for CO2 and volatile organics if used: CO2 was trapped in 0.25 M NaOH. Two scrubbers containing 100 mL each were connected in series to the test vessels. The initial IC value of the 0.25 M NaOH was separately determined in each flask.

SAMPLING
- Sampling frequency: day 0, 2, 4, 7, 9, 11, 14, 18, 23 and 29
- Sampling method: From each front scrubber flask, 10 samples were taken in order to determine the emitted CO2. The sample volume was 1 mL. The resulting change in the volume of the front flask was considered in the calculation of emitted CO2

CONTROL AND BLANK SYSTEM
- Inoculum blank: 2
- Abiotic sterile control: 1
- Toxicity control: 1
- Other: Positive control: 2; Apparatus blank (mineral medium only): 2
Reference substance
Reference substance:
aniline

Results and discussion

% Degradation
Parameter:
% degradation (CO2 evolution)
Value:
9
Sampling time:
29 d

BOD5 / COD results

Results with reference substance:
Degradation of the positive control was 80 % after 9 days.

Any other information on results incl. tables

Table 1: Net IC-values in mg/L of front scrubber flasks

 

Day

Blank Control 1

Blank Control 2

Positive Control 1

Positive Control 2

Test 1

Test 2

Abiotic Control

Toxicity Control

0

2.3

2.6

2.4

2.6

2.0

2.0

2.1

2.1

2

2.7

17.1

8.7

10.0

14.6

14.5

2.5

4.6

4

4.0

28.2

25.8

84.3

24.1

24.5

4.1

82.1

7

6.9

38.2

199.1

201.3

34.4

36.4

3.7

159.5

9

11.4

45.2

279.9

278.7

42.6

45.4

3.2

263.6

11

13.9

49.2

307.6

324.3

47.0

50.3

6.1

317.0

14

18.2

52.2

339.1

342.9

49.7

56.7

3.2

333.4

18

13.5

49.4

339.4

345.5

56.5

64.7

2.2

351.2

23

22.6

57.4

374.7

369.4

61.4

69.2

2.0

356.5

29

23.8

60.9

374.8

375.9

63.9

77.5

1.1

367.9

Table 2: Net IC-values in mg/L of back scrubber flasks

 

Day

Blank Control 1

Blank Control 2

Positive Control 1

Positive Control 2

Test 1

Test 2

Abiotic Control

Toxicity Control

0

2.3

2.3

2.2

2.0

2.0

2.2

2.0

2.2

29

2.2

2.6

2.4

2.8

4.1

2.1

2.1

2.5

Table 3: Degradation values in %

 

Day

Positive Control 1

Positive Control 2

Positive Control Mean

Test 1

Test 2

Test Mean

Abiotic Control

Toxicity Control

2

-0.4

0.0

-0.2

1.7

1.7

1.7

0.1

-0.8

4

3.2

22.2

12.7

2.8

2.9

2.8

0.6

10.8

7

57.1

57.7

57.4

3.9

4.6

4.3

0.5

22.2

9

80.5

80.1

80.3

4.7

5.6

5.1

0.3

37.7

11

87.4

92.6

90.0

5.0

6.1

5.5

1.2

45.2

14

95.2

96.3

95.8

4.7

6.8

5.7

0.3

46.7

18

95.4

97.3

96.4

7.8

10.4

9.1

0.0

49.6

23

102.6

101.0

101.8

6.6

9.0

7.8

0.0

48.5

29

100.8

101.3

101.1

7.3

10.7

9.0

-0.3

49.4

Table 4: Validity criteria for OECD 301B

Criterion from the guideline

Outcome

Validity criterion fulfilled

Difference of extremes of replicate values of the removal of the test chemical at the plateau, at the end of the test or at the end of the 10-d window, as appropriate, is less than 20%.

 3.4%

 yes

Percentage degradation of the reference compound reached the pass level by day 14 (≥ 60%).

Pass level reached on day 9

 yes

The toxicity control should degrade to at least 35% (based on DOC) or at least 25% (based on ThOD or ThCO2) within 14 d.

 46.7%

 yes

The IC content of the test substance suspension in the mineral medium at the beginning of the test must be less than 5% of the TC.

 0%

 yes

The total CO2 evolution in the inoculum blank at the end of the test should not normally exceed 40 mg/L medium.

 8.9 mg/L

 yes

Applicant's summary and conclusion

Validity criteria fulfilled:
yes
Remarks:
For further details please refer to “Any other information on results incl. tables”.
Interpretation of results:
under test conditions no biodegradation observed