Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
flash point, other
Remarks:
flash point of non-flammable liquid
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2017
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
guideline study
Remarks:
Non-GLP study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2017
Report date:
2017

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
other: ASTM D-92
Deviations:
no
GLP compliance:
no
Type of method:
equilibrium method
Remarks:
Open cup

Test material

1
Chemical structure
Reference substance name:
Decanoic acid, mixed diesters with octanoic acid and triethylene glycol
EC Number:
271-517-9
EC Name:
Decanoic acid, mixed diesters with octanoic acid and triethylene glycol
Cas Number:
68583-52-8
Molecular formula:
C10-H20-O2.C8-H16-O2.C6-H14-O4
IUPAC Name:
Decanoic acid, mixed diesters with octanoic acid and triethylene glycol
Specific details on test material used for the study:
Test material purity was 99%+, with no known impurities. Material was stored at ambient conditions. The test material lot number was 5060049. No evidence of chemical instability of the substance under test conditions.

Results and discussion

Flash point
Key result
Flash point:
> 200 °C
Atm. press.:
ca. 1 atm

Applicant's summary and conclusion