Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Partition coefficient

Currently viewing:

Administrative data

Endpoint:
partition coefficient
Type of information:
(Q)SAR
Adequacy of study:
key study
Study period:
January 29th, 2018
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
results derived from a valid (Q)SAR model and falling into its applicability domain, with adequate and reliable documentation / justification
Justification for type of information:
The experimental study provided only a 'greater than' value, of limited use for risk assessment, so this calculated value is considered to be more reliable.
1. SOFTWARE
iSafeRat® HA-QSAR toolbox v2.4
2. MODEL (incl. version number)
iSafeRat® holistic HA-QSAR v1.8
3. SMILES OR OTHER IDENTIFIERS USED AS INPUT FOR THE MODEL
CCCCC(CC)C(=O)OC(C)C
4. SCIENTIFIC VALIDITY OF THE (Q)SAR MODEL
See attached QMRF
5. APPLICABILITY DOMAIN
See attached QPRF
6. ADEQUACY OF THE RESULT
See attached QPRF
Cross-reference
Reason / purpose for cross-reference:
reference to other study
Reference
Endpoint:
partition coefficient
Type of information:
experimental study
Adequacy of study:
supporting study
Study period:
2 to 30 August 2017.
Reliability:
3 (not reliable)
Rationale for reliability incl. deficiencies:
guideline study
Justification for type of information:
The test method gave only a 'greater than' result of >4.04.
The analytical determination is not reliable: in the water phase (blank pre-saturated and test layer), octanol peak is tailing, hiding the substance signal, giving poor resolution and a higher limit of quantitation (LoQ). The water phase is diluted for analysis, giving a lower LoQ, and only a limit value.
For these reasons, a calculated value was considered more reliable (see cross-reference).
Reason / purpose for cross-reference:
reference to other study
Qualifier:
according to guideline
Guideline:
OECD Guideline 107 (Partition Coefficient (n-octanol / water), Shake Flask Method)
Deviations:
not specified
GLP compliance:
no
Other quality assurance:
ISO/IEC 17025 (General requirements for the competence of testing and calibration laboratories)
Type of method:
flask method
Partition coefficient type:
octanol-water
Analytical method:
gas chromatography
mass spectrometry
Type:
log Pow
Partition coefficient:
> 4.04
Temp.:
25 °C
pH:
6.1 - 7.3
Conclusions:
Log Pow >4.04 at 25 °C, but 'greater than value' of limited value for evaluation and risk assessment.

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2018
Report date:
2018

Materials and methods

Test guideline
Qualifier:
equivalent or similar to guideline
Guideline:
OECD Guideline 107 (Partition Coefficient (n-octanol / water), Shake Flask Method)
Deviations:
not applicable
Remarks:
QSAR model.
Principles of method if other than guideline:
The iSafeRat® HA-QSAR predicts log KOW using the chemical structure as an input.
The method is termed as “the Core-Centered Substitution Method” (C2SM) and is
based on a substitution-based approach, a methodology which has been commonly
implemented for the estimation of log KOW and is readily found in the literature.
GLP compliance:
no
Type of method:
calculation method (fragments)
Partition coefficient type:
octanol-water

Test material

Constituent 1
Chemical structure
Reference substance name:
Isopropyl 2-ethylhexanoate
EC Number:
266-549-5
EC Name:
Isopropyl 2-ethylhexanoate
Cas Number:
67024-46-8
Molecular formula:
C11H22O2
IUPAC Name:
isopropyl 2-ethylhexanoate
Test material form:
liquid

Results and discussion

Partition coefficient
Key result
Type:
log Pow
Partition coefficient:
4.4
Temp.:
25
Remarks on result:
other: pH not available for QSAR study.

Applicant's summary and conclusion

Conclusions:
The log KOW is calculated as follows: 4.4 at 25°C.