Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Ecotoxicological information

Toxicity to microorganisms

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
activated sludge respiration inhibition testing
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
guideline study without detailed documentation
Qualifier:
equivalent or similar to guideline
Guideline:
OECD Guideline 209 (Activated Sludge, Respiration Inhibition Test
GLP compliance:
not specified
Test organisms (species):
activated sludge
Details on inoculum:
- Inoculum: a mixed population of activated sewage sludge microorganisms.
- Source: the aeration Stage of Severn Trent PLC Sewage Treatment Plant, Belper, Derbyshire.
- Preparation: the sample was maintained at 21 °C with continuous aeration and used on the day of collection.
- pH: the pH was buffered to pH 7.0 with sodium hydroxide solution.
- Suspended solids level: adjusted to 3.9 g/l prior to use.
Test type:
static
Water media type:
freshwater
Limit test:
yes
Total exposure duration:
3 h
Nominal and measured concentrations:
1000 mg/l
Details on test conditions:
TEST SYSTEM
- No. of vessels per concentration: 3 replicates
- No. of vessels per control: 2 replicates

RANGE FINDING STUDY
- No. of vessels per concentration: 1 replicates
- No. of vessels per control: 2 replicates
- Concentrations: 10, 100 and 1000 mg/l
- Results: at the highest tested dose, the inhibition of respiration was of 11 %; variation between controls was of ± 4 %.
Reference substance (positive control):
yes
Remarks:
3,5-dichlorophenol
Duration:
3 h
Dose descriptor:
IC50
Effect conc.:
> 1 000 mg/L
Nominal / measured:
nominal
Conc. based on:
test mat.
Basis for effect:
inhibition of total respiration
Results with reference substance (positive control):
IC50 (3h): 9.2 mg/l

MAIN STUDY

Vessel O2 consumption rate mg/O2/l/min % inhibition
Control 1 0.42 -
Control 2 0.48 -
Variation ± 7 % -
Test item 1000 mg/l 0.44 2
Test item 1000 mg/l 0.44 2
Test item 1000 mg/l 0.44 2
Reference 3.2 mg/l 0.37 18
Reference 32 mg/l 0.06 87

RANGE FINDING STUDY

Vessel O2 consumption rate mg/O2/l/min % inhibition
Control 1 0.29 -
Control 2 0.27 -
Test item 10 mg/l 0.31 <11>
Test item 100 mg/l 0.26 7
Test item 1000 mg/l 0.25 11
Reference 3.2 mg/l 0.26 7
Reference 32 mg/l 0.03 39
Conclusions:
IC10 (3h) > 1000 mg/l (nominal)
Executive summary:

The inhibitory effect of test item on the oxygen consumption of activated sludge microorganisms was investigated under aerobic static conditions. The exposure time of the test substance on the activated sludge was 3 hours. A preliminary range finding test was conducted at the nominal concentrations of 10, 100 and 1000 mg/l. Due to absence of significant impact, 1000 mg/l was chosen as limit concentration for the main study. In the main experiment, 3 replicates were assayed for the test item and 2 replicates were run as control. 3,5-dichlorophenol was used os reference control.

At the applied test concentration (i.e. 1000 mg/l), the test substance showed no significant toxic effects to the activated sludge: the substance caused an inhibition of the 2 %. Positive reference substance showed an inhibition effect in the historical range.

Conclusion

IC10 (3h) > 1000 mg/l (nominal)

Description of key information

IC10 (3h) > 1000 mg/l (nominal)

Key value for chemical safety assessment

EC10 or NOEC for microorganisms:
1 000 mg/L

Additional information

The inhibitory effect of test item on the oxygen consumption of activated sludge microorganisms was investigated under aerobic static conditions, following the a method and procedures comparable to those described into the OECD guideline 209. At the applied test concentration (i.e. 1000 mg/l), the test substance showed no significant toxic effects to the activated sludge: the substance caused an inhibition of the 2 %. Positive reference substance showed an inhibition effect in the historical range.

A second experiment, conducted on a less pure lot, confirmed the outcomes obtained in the key study. The inhibitory effect of the test item was investigated in a respiratory test. Only a slight inhibition (19.8 %) of the respiration rate was recorded. The IC50 (3h) was determined higher than 100 mg/l.