Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
basic toxicokinetics, other
Remarks:
Bioaccessibility
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2016-01-13 to 2016-03-24
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Remarks:
Bioaccessibility testing: loading of 100 mg/L; five artificial physiological media (GST, GMB, ALF, ASW, PBS) agitated at 100 rpm, at 37°C ± 2°C; sampling after 2h and 24h; determination of Cr, Co and Zn concentrations after filtration by ICP-OES and ICP-MS.

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2016
Report date:
2016

Materials and methods

Objective of study:
bioaccessibility (or bioavailability)
Test guidelineopen allclose all
Qualifier:
equivalent or similar to guideline
Guideline:
OECD Series on Testing and Assessment No. 29 (23-Jul-2001): Guidance document on transformation/dissolution of metals and metal compounds in aqueous media
Deviations:
yes
Remarks:
Bioaccessibility testing: loading of 100 mg/L; five artificial physiological media agitated at 100, at 37°C; sampling after 2h and 24h; determination of Fe, Ti and Al concentrations after filtration by ICP-MS.
Qualifier:
according to guideline
Guideline:
other: EEC guideline SANCO/3029/99 rev. 4 dated 11/07/00: Working document “Guidance for generating and reporting methods of analysis in support of residue data requirements for Annex II (part A, Section 4) and Annex III (part A, Section 5)
Deviations:
not specified
Principles of method if other than guideline:
The dissolved amount of the test item (single loading of 100 mg/L) was quantified by the mass concentration (IPC-MS) of iron, titanium and aluminium in five artificial physiological test media (phosphate-buffered saline (PBS) (pH 7.2), artificial interstitial fluid or Gamble’s solution (pH 7.4), artificial sweat solution (pH 6.5), artificial lysosomal fluid (pH 4.5)) and artificial gastric fluid (pH 1.5), which were selected to simulate relevant human-chemical interactions. Three replicates vessels and one control vessel of each medium were sampled twice after 2h and 24h agitation (100 rpm) at 37 °C. Blanks (replicates and control) were sampled twice after 30 min.
Repeatability and recovery tests were performed by spiking each test medium with known amounts of iron, titanium and aluminium at two levels (1 µg/L for low level and 10 µg/L for the high level). Three Control, three Spike Low and three Spike High samples were shaken at 37°C for 24 hours at 100 r.p.m for each medium and tested twice by ICP-MS for dissolved iron, titanium and aluminium concentrations.

The study was performed in compliance with following method: Stopford W, Turner J, Cappelini D, Brock T 2004. Bioaccessibility testing of Cobalt compounds. Journal of Environmental Monitoring 5:675-680.
GLP compliance:
yes (incl. QA statement)
Remarks:
signed 2014-10-22

Test material

Constituent 1
Chemical structure
Reference substance name:
Iron titanium pseudobrookite
EC Number:
603-450-1
Cas Number:
1310-39-0
Molecular formula:
FexTiOy 1.2 ≤ x ≤ 2.1 y = 3/2 x + 2
IUPAC Name:
Iron titanium pseudobrookite
Test material form:
solid: particulate/powder
Details on test material:
- Name of test material (as cited in study report): Pseudobrookite; Pigment Brown 48
- Physical state: brown powder, odourless
- Density: 4.25 g/cm³

Test animals

Species:
other: in vitro (simulated human body fluids)
Details on test animals or test system and environmental conditions:
Test principle in brief:
- five different artificial physiological media,
- single loading of test substance of 100 mg/L,
- samples taken after 2 and 24 hours agitation (100 rpm) at 37 °C,
- three replicates and one control per artificial media were tested twice; two additional blank samples were taken from the replicates and control of each medium; measurement (by IPC-MS) of dissolved iron, titanium and aluminium concentrations after filtration
- Repeatability and recovery tests were performed by spiking each test medium with known amounts of iron, titanium and aluminium at two levels (1 µg/L for low level and 10 µg/L for the high level)

The aim of this test was to assess the dissolution of IPC-2018-007 (pseudobrookite) in five artificial physiological media: Artificial lysosomal fluid (ALF, pH = 4.5), Artificial sweat solution (ASW, pH = 6.5), artificial interstitial fluid or Gamble´s solution (GMB, pH = 7.4), Artificial gastric fluid (GST, pH = 1.5), Phosphate buffered saline (PBS, pH = 7.2). The test media were selected to simulate relevant human-chemical interactions (as far as practical), i.e. a substance entering the human body by ingestion into the gastrointestinal tract and by inhalation.

Administration / exposure

Duration and frequency of treatment / exposure:
Samples were taken after 2 h and 24h.
Doses / concentrations
Dose / conc.:
0.1 other: g of the test item /L artifical media
Details on study design:
EQUIPMENT
- Inductively coupled plasma-mass spectrometer (ICP-MS), Agilent Technologies HP7700
- Analytical balance, Mettler AG204
- Mechanical shaker, IKA KS 4000 I control
- pH meter VWR pH 1000 L
- Dissolved oxygen meter, WTW OXY 315.
- Chronometer Hanhart Profil 1
- Syringe filter PTFE 0.45 µm, diameter 25 mm
- Data logger, Testo 174-T
- Digital thermometer and probe
- Laboratory Water Purification Systems, Sartorius Arium® 611
- Refrigerator, Fiocchetti Scientific ECT-F Control

REAGENTS
- Water, HPLC grade obtained from the Laboratory Water Purification System
- Standard solutions at pH 4.00, pH 7.00 and at pH 10.00 (Merck)
- Ammonia solution 25 %, NH4OH aqueous (Merck)
- Hydrochloric acid, ≥ HCl 30 % TraceSELECT, for trace analysis (Fluka)
- Nitric acid ≥ 69 %, Trace SELECT,for trace analysis (Fluka)
- ICP-MS Internal Standard Mix solution 100 mg/L (Li6, Sc, Ge, Rh, In, Tb, Lu, Bi) 10 % HNO3, Agilent Technologies.

Certified Reference Material
- IQC-026: Multi-element analytical standard solution at about 100 µg/mL of iron (Fe), titanium (Ti) and aluminium (Al), supplied by Ultra Scientific:
Batch number: CL-4020
Expiration date: 30/11/2017
Certified value: Iron: 100.0 ± 0.5 µg/mL, Titanium: 100.1 ± 0.5 µg/mL, Aluminium: 100.2 ± 0.5 µg/mL
- TM-25.4: A trace element fortified sample (filtered and diluted Lake Ontario water preserved with in 0.2 % nitric acid), supplied by Environment Canada.
Batch no.: 0815
Expiry date: october 2017
Certified value: Iron: 31.0 ± 5.7 µg/L, Titanium: 25.2 ± 1.9 µg/L, Aluminium: 30.0 ± 3.5 µg/L

Instrumental conditions
- Detector: ICP/MS
- Power: 1550 W
- Carrier gas: 0.85 L/min
- Replicates: 3 times
Sample introduction setting (peristaltic pump)
- Pump rate: 0.1 rps
- Iron (Fe): m/z 56 (quantitative)
- Titanium (Ti): m/z 47(quantitative)
- Aluminium (Al): m/z 27 (quantitative)
- Scandium (Sc): m/z 45 (used as internal standard correction for Al and Ti)
- Germanium (Ge): m/z 72 (used as internal standard correction for Fe)

Quality criteria of the method
Linearity: from 0.5 to 200.20 µg/L (correlation coefficient > 0.99 for Iron, Titanium and Aluminium).
L.O.Q.: 1 µg/L (ppb) defined as the lowest fortification level
L.O.D.: 0.5 µg/L (ppb) defined as 50 % of the lowest fortification level
I.D.L.: 0.5 µg/L (ppb) defined as the lowest calibration level
Precision: +/- 10 % in the linearity range
Calibration: nominal concentrations 0.50, 1.00, 2.00, 5.00, 10.00, 20.00, 50.00, 100.00 and 200.00 µg/L (ppb) of iron, titanium and aluminium.

Results and discussion

Toxicokinetic / pharmacokinetic studies

Toxicokinetic parameters
Toxicokinetic parameters:
other: bioaccessibility
Remarks:
Dissolution of Fe at a loading of 0.1 g/L: GST 2h: 25.45 ± 1.9 µg/L; dissolution of Ti at a loading of 0.1 g/L: GST 2h 15.68 ± 1.66 µg/L; dissolution of Al at a loading of 0.1 g/L: GST 2h: 57.85 ± 2.77 µg/L.

Bioaccessibility (or Bioavailability)

Bioaccessibility (or Bioavailability) testing results:
IRON concentrations in five different artificial body fluids (loading of 100 mg test item/L medium)
Phosphate buffered saline (PBS) (pH 7.2): < 1 (Control); n.d. (2 h*, 24 h*)
Artificial interstitial fluid (pH 7.4): n.d. (Control,2 h*, 24 h*)
Artificial sweat solution (pH 6.5): n.d. (Control, 2 h*, 24 h*)
Artificial lysosomal fluid (pH 4.5): n.d. (Control, 2 h*, 24 h*)
Artificial gastric fluid (pH 1.5): 4.39 µg/L ± 0.38 µg/L (Control); 25.45 ± 1.9 µg/L (2 h*); 177.81 ± 2.55 µg/L (24 h*)
n.d.: lower than the Limit of Detection (L.O.D. = 0.5 µg/L for Fe)
< 1: lower than the method Limit of Quantification (L.O.Q. = 1 µg/L for Fe) but higher than the Limit of Detection (L.O.D. = 0.5 µg/L for Fe).
*: This value was calculated subtracting the relevant Control sample value, in order to consider the contribution of the test medium.
The between-vessel variation was less than 20 % in accordance with OECD Series No. 29.

TITANIUM concentrations in five different artificial body fluids (loading of 100 mg test item/L medium)
Phosphate buffered saline (PBS) (pH 7.2): n.d. (Control, 2 h*, 24 h*)
Artificial interstitial fluid (pH 7.4): n.d. (Control, 2 h*, 24 h*)
Artificial sweat solution (pH 6.5): n.d. (Control, 2 h*, 24 h*)
Artificial lysosomal fluid (pH 4.5): n.d. (Control, 2 h*, 24 h*)
Artificial gastric fluid (pH 1.5): n.d. (Control); 15.68 ± 1.66 µg/L (2 h*); 105.76 ± 2.61 µg/L (24 h*)
n.d.: lower than the Limit of Detection (L.O.D. = 0.5 µg/L for Ti)
*: This value was calculated subtracting the relevant Control sample value, in order to consider the contribution of the test medium.
The between-vessel variation was less than 20 % in accordance with OECD Series No. 29.

ALUMINIUM concentrations in five different artificial body fluids (loading of 100 mg test item/L medium)
Phosphate buffered saline (PBS) (pH 7.2): 3.27 ± 0.20 µg/L (Control); n.d. (2 h*); 3.76 ± 0.23 µg/L (24 h*)
Artificial interstitial fluid (pH 7.4): 1.48 ± 0.00 µg/L (Control); 2.03 ± 0.06 µg/L (2 h*); 7.50 ± 0.13 µg/L (24 h*)
Artificial sweat solution (pH 6.5): 1.40 ± 0.12 µg/L (Control); 1.45 ± 0.04 µg/L (2 h*); 1.69 ± 0.07 µg/L (24 h*)
Artificial lysosomal fluid (pH 4.5): n.d. (Control, 2 h*, 24 h*)
Artificial gastric fluid (pH 1.5): 5.24 ± 0.30 µg/L (Control); 57.85 ± 2.77 µg/L (2 h*); 138.36 ± 3.83 µg/L (24 h*)
n.d.: lower than the Limit of Detection (L.O.D. = 0.5 µg/L for Al)
*: This value was calculated subtracting the relevant Control sample value, in order to consider the contribution of the test medium.
The between-vessel variation was less than 20 % in accordance with OECD Series No. 29.

Any other information on results incl. tables

Linearity

The nominal range of iron, titanium and aluminium concentrations, from 0.50 µg/L to 200.00 µg/L, was found to be linear (correlation coefficient > 0.99).

The instrumental limit of detection (I.D.L.) defined as the lowest calibration level, was 0.5 µg/L for iron, titanium and aluminium.

The limit of quantification (L.O.Q.) of the method was fixed at 1 µg/L, defined as the lowest fortification level.

The limit of detection (L.O.D.) of the method, defined as 50 % of the lowest fortification level, was 0.5 µg/L.

Iron, titanium and aluminium concentrations lower than the L.O.D. were classified as not detected (n.d.), concentrations higher than the L.O.D. but lower than the L.O.Q. were designated as <1 µg/L.

Repeatability (Precision) and Accuracy (Recovery)

Since the fortification levels for the recovery test were 1 µg/L and 10 µg/L, the linear calibration performed for recovery quantification ranged from 0.50 µg/L to 200.20 µg/L.

For precision, the SANCO/3029/99 rev. 4 guideline requires an RSD to be lower than 20 % for all tested media and fortification levels.

For accuracy, the SANCO/3029/99 rev. 4 guideline requires individual recovery values in the range from 70 to 110 % with a mean between 80 to 100 % for all tested media and fortification levels.

From the results of the accuracy test it can be concluded that there was not a matrix effect and contamination (e.g. by the filter procedure) did not occur during sample processing.

From data obtained, these criteria were fulfilled and therefore precision and accuracy of the analytical method is acceptable.

Mean recovery of fortified samples in five different artificial body fluids

 

Phosphate buffered saline (PBS)

(pH 7.2)

Artificial sweat solution

(pH 6.5)

Artificial

interstitial

fluid

(pH 7.4)

Artificial

lysosomal fluid

(pH 4.5)

Artificial

gastric fluid

(pH 1.5)

Fe spiked low

(1 µg/L)

89.93 % ± 8.59 %

82.74 % ± 0.98 %

82.58 % ± 0.38 %

82.74 % ± 0.67 %

83.63 % ± 0.86 %

Fe spiked high

(10 µg/L)

89.67 % ± 1.64 %

94.68 % ± 0.91 %

98.41 % ± 0.93 %

90.04 % ± 0.73 %

88.55 % ± 0.09 %

Ti spiked low

(1 µg/L)

86.38 % ± 1.23 %

91.09 % ± 1.10 %

87.03 % ± 0.36 %

83.11 % ± 0.57 %

86.15 % ± 1.17 %

Ti spiked high

(10 µg/L)

96.20 % ± 0.50 %

99.71 % ± 0.13 %

94.42 % ± 0.27 %

95.80 % ± 1.29 %

97.90 % ± 0.78 %

Al spiked low

(1 µg/L)

84.52 % ± 1.44 %

82.39 % ± 0.38 %

83.00 % ± 0.08 %

82.89 % ± 0.20 %

83.47 % ± 0.23 %

Al spiked high

(10 µg/L)

86.54 % ± 1.31 %

91.23 % ± 1.19 %

93.23 % ± 0.83 %

93.82 % ± 0.66 %

87.77 % ± 0.34 %

Tempearture, pH and dissolved oxygen after 24 h in five different artificial body fluids

Media Temperature pH Dissolved oxygen
Phosphate buffered saline (PBS) (pH 7.2) 36.98 °C ± 0.08 °C 7.217 ± 0.046 88.3 % ± 3.1 %
Artificial interstitial fluid (pH 7.4) 37.01 °C ± 0.04 °C 7.400 ± 0.012 83.9 % ± 5.4 %
Artificial sweat solution (pH 6.5) 36.84 °C ± 0.07 °C 6.519 ± 0.024 85.4 % ± 3.1 %
Artificial lysosomal fluid (pH 4.5) 37.01 °C ± 0.05 °C 4.847 ± 0.028 86.0 % ± 4.5 %
Artificial gastric fluid (pH 1.5) 36.89 °C ± 0.04 °C 1.491 ± 0.010 89.1 % ± 6.4 %

Applicant's summary and conclusion

Conclusions:
IRON concentrations in five different artificial body fluids (loading of 100 mg test item/L medium)
Phosphate buffered saline (PBS) (pH 7.2): < 1 (Control); n.d. (2 h*, 24 h*)
Artificial interstitial fluid (pH 7.4): n.d. (Control,2 h*, 24 h*)
Artificial sweat solution (pH 6.5): n.d. (Control, 2 h*, 24 h*)
Artificial lysosomal fluid (pH 4.5): n.d. (Control, 2 h*, 24 h*)
Artificial gastric fluid (pH 1.5): 4.39 µg/L ± 0.38 µg/L (Control); 25.45 ± 1.9 µg/L (2 h*); 177.81 ± 2.55 µg/L (24 h*)
n.d.: lower than the Limit of Detection (L.O.D. = 0.5 µg/L for Fe)
< 1: lower than the method Limit of Quantification (L.O.Q. = 1 µg/L for Fe) but higher than the Limit of Detection (L.O.D. = 0.5 µg/L for Fe).
*: This value was calculated subtracting the relevant Control sample value, in order to consider the contribution of the test medium.
The between-vessel variation was less than 20 % in accordance with OECD Series No. 29.

TITANIUM concentrations in five different artificial body fluids (loading of 100 mg test item/L medium)
Phosphate buffered saline (PBS) (pH 7.2): n.d. (Control, 2 h*, 24 h*)
Artificial interstitial fluid (pH 7.4): n.d. (Control, 2 h*, 24 h*)
Artificial sweat solution (pH 6.5): n.d. (Control, 2 h*, 24 h*)
Artificial lysosomal fluid (pH 4.5): n.d. (Control, 2 h*, 24 h*)
Artificial gastric fluid (pH 1.5): n.d. (Control); 15.68 ± 1.66 µg/L (2 h*); 105.76 ± 2.61 µg/L (24 h*)
n.d.: lower than the Limit of Detection (L.O.D. = 0.5 µg/L for Ti)
*: This value was calculated subtracting the relevant Control sample value, in order to consider the contribution of the test medium.
The between-vessel variation was less than 20 % in accordance with OECD Series No. 29.

ALUMINIUM concentrations in five different artificial body fluids (loading of 100 mg test item/L medium)
Phosphate buffered saline (PBS) (pH 7.2): 3.27 ± 0.20 µg/L (Control); n.d. (2 h*); 3.76 ± 0.23 µg/L (24 h*)
Artificial interstitial fluid (pH 7.4): 1.48 ± 0.00 µg/L (Control); 2.03 ± 0.06 µg/L (2 h*); 7.50 ± 0.13 µg/L (24 h*)
Artificial sweat solution (pH 6.5): 1.40 ± 0.12 µg/L (Control); 1.45 ± 0.04 µg/L (2 h*); 1.69 ± 0.07 µg/L (24 h*)
Artificial lysosomal fluid (pH 4.5): n.d. (Control, 2 h*, 24 h*)
Artificial gastric fluid (pH 1.5): 5.24 ± 0.30 µg/L (Control); 57.85 ± 2.77 µg/L (2 h*); 138.36 ± 3.83 µg/L (24 h*)
n.d.: lower than the Limit of Detection (L.O.D. = 0.5 µg/L for Al)
*: This value was calculated subtracting the relevant Control sample value, in order to consider the contribution of the test medium.
The between-vessel variation was less than 20 % in accordance with OECD Series No. 29.