Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Particle size distribution (Granulometry)

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
6 October 2010
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
OECD Guideline 110 (Particle Size Distribution / Fibre Length and Diameter Distributions)
Version / remarks:
Screening Test
Principles of method if other than guideline:
The method used is based on a procedure designed to comply with that given in 'Particle size distribution, fibre length and diameter distribution', June 1996 European Commission technical guidance document, which satisfies the requirements of OECD Guideline 110
GLP compliance:
yes (incl. QA statement)
Type of method:
sieving
Type of particle tested:
primary particle
No.:
#1
Size:
< 100 µm
Distribution:
56.7 %

The results of the sieving procedure are shown below:

 Measurement

Result 

Mass of test item transferred to sieve 

10.15g

 Mass of test item passed through sieve

5.76g

Proportion of test item <100 µm 

56.7%
Conclusions:
The proportion of Ruthenium trichloride (hydrate) <100 μm was 56.7%
Executive summary:

Walker and White (2011) is a GLP compliant study following OECD guideline 110 (screening test) and is considered suitable for use as the key study for this endpoint. The proportion of ruthenium trichloride (hydrate) < 100 μm is 56.7%.

Description of key information

The proportion of ruthenium trichloride (hydrate) <100 μm was 56.7%.

Additional information

Walker and White (2011) is a GLP compliant study following OECD guideline 110 (screening test) and is considered suitable for use as the key study for this endpoint. The proportion of ruthenium trichloride (hydrate) < 100 μm is 56.7%.