Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Viscosity

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
viscosity
Type of information:
experimental study
Adequacy of study:
key study
Study period:
23/07/2010
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
test procedure in accordance with generally accepted scientific standards and described in sufficient detail
Qualifier:
according to guideline
Guideline:
other: No guideline listed
Principles of method if other than guideline:
The viscosity was measured using the Haake Rotovisco 1 (RV1) rotational rheometer. Samples were conditioned at 25 °C.
GLP compliance:
no
Type of method:
rotational viscometer (dynamic)
Key result
Temp.:
other: 25 °C
Parameter:
dynamic viscosity (in mPa s)
Value:
ca. 1 007
Remarks on result:
other: Values can vary by +/- 10 to 20% depending on the natural variation of the linseed oil crop.
Conclusions:
The samples tested were in the range 899 -1200 mPa s, mean 1007 mPa s at 25 °C.
Executive summary:

The samples tested were in the range 899 -1200 mPa s, with a mean value of 1007 mPa s at 25 °C.

Values can vary by +/- 10 to 20% depending on the natural variation of the linseed oil crop.

Description of key information

The samples tested were in the range 899 -1200 mPa s, with a mean value of 1007 mPa s at 25 °C.

Values can vary by +/- 10 to 20% depending on the natural variation of the linseed oil crop.

Key value for chemical safety assessment

Viscosity:
1 007 mPa · s (dynamic)