Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Particle size distribution (Granulometry)

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2020-12-16
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
OECD Guideline 110 (Particle Size Distribution / Fibre Length and Diameter Distributions - Method A: Particle Size Distribution (effective hydrodynamic radius)
Version / remarks:
1981
Deviations:
no
Qualifier:
according to guideline
Guideline:
ISO 13320 (Particle size analysis - Laser diffraction methods)
Version / remarks:
2009
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Type of method:
Laser scattering/diffraction
Type of distribution:
volumetric distribution
Percentile:
D10
Mean:
103.4 µm
St. dev.:
4.8
Key result
Percentile:
D50
Mean:
443.6 µm
St. dev.:
2.3
Percentile:
D90
Mean:
783.1 µm
St. dev.:
12.7

Two test series of 3 measurements each were performed with the test item. The values represented below are rounded values. The calculation of the average was carried out with the original not rounded values.


 










































 



Test series 1 [µm]



Standard deviation



Test series 2 [µm]



Standard deviation



Average [µm]



Standard deviation



D10



98.6



2.4



108.2



10.8



103.4



4.8



D50



445.9



5.2



441.2



3.3



443.6



2.3



D90



770.4



13.9



795.8



25.9



783.1



12.7


Conclusions:
The median particle size (D50) was determined to be 443.6 µm.
Executive summary:

A study was conducted according to OECD Test Guideline 110 and ISO 13320 to determine the particle size distribution using the laser diffraction method with dry dispersion. Two test series of 3 measurements each were performed with the test item. The D10, D50 and D90 percentile were determined as D10 = 103.4 µm, D50 = 443.6 µm and D90 = 783.1 µm, respectively.

Description of key information

The median particle size (D50) was determined to be 443.6 µm (reference 4.5-1).

Additional information

A study was conducted according to OECD Test Guideline 110 and ISO 13320 to determine the particle size distribution using the laser diffraction method with dry dispersion. Two test series of 3 measurements each were performed with the test item. The D10, D50 and D90 percentile were determined as D10 = 103.4 µm, D50 = 443.6 µm and D90 = 783.1 µm, respectively.