Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Particle size distribution (Granulometry)

Administrative data

Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: guideline study according to GLP standard

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2010

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
OECD Guideline 110 (Particle Size Distribution / Fibre Length and Diameter Distributions)
GLP compliance:
yes (incl. QA statement)
Type of distribution:
volumetric distribution

Test material

Constituent 1
Chemical structure
Reference substance name:
Lead cyanamidate
EC Number:
244-073-9
EC Name:
Lead cyanamidate
Cas Number:
20837-86-9
Molecular formula:
CN2.Pb
IUPAC Name:
λ²-lead(2+) (azanidylenemethylidene)azanide

Results and discussion

Particle size
Percentile:
D50
Mean:
µm
Remarks on result:
other: Migrated from fields under 'Mass median diameter' as D50 percentile. No source field for Standard deviation.
Particle size distribution at different passagesopen allclose all
No.:
#1
Size:
200.61 µm
Distribution:
87.42 %
No.:
#2
Size:
91.35 µm
Distribution:
75.85 %
No.:
#3
Size:
65.9 µm
Distribution:
68.9 %
No.:
#4
Size:
52.2 µm
Distribution:
60.38 %
No.:
#5
Size:
38.2 µm
Distribution:
52.95 %
No.:
#6
Size:
22.95 µm
Distribution:
48.97 %
No.:
#7
Size:
14.23 µm
Distribution:
36.59 %
No.:
#8
Size:
10.54 µm
Distribution:
32.52 %
No.:
#9
Size:
5.39 µm
Distribution:
19.7 %
No.:
#10
Size:
2.22 µm
Distribution:
5.15 %

Any other information on results incl. tables

Approx. 13% (6% of 100%-value) of the particles are larger than 200.61 µm.

In three experimentes sedimentation took place already before the first sampling time: in the three experimentes, 8.47%, 6,25% resp. 8.12 % of the particles were not retrieved when determining the 100% value. These particles must be considered as larger than the upper Stokes diameter.

For the test item the mentioned particle size distribution was found.

Applicant's summary and conclusion

Conclusions:
The presented data are reliable and adequate.