Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
11 December 2017 - 30 May 2018
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.10 (Flammability (Solids))
Deviations:
no
GLP compliance:
yes
Test procedure:
burning rate test: preliminary screening test
Remarks on result:
other: The test item was observed to burn at point of contact with the burner flame. The test item ignited during the two minutes of application of the burner but the flame extinguished once the burner was removed. The flame did not propagate along the train.

The test item was observed to burn at point of contact with the burner flame. The test item ignited during the two minutes of application of the burner but the flame extinguished once the burner was removed. The flame did not propagate along the train

Interpretation of results:
not classified based on GHS criteria
Conclusions:
The test item is concluded to be not highly flammable (not classified based on GHS criteria) as it ignited during the two minutes of application of the burner but the flame extinguished once the burner was removed. The flame did not propagate along the train.
Executive summary:

The flammability of the test item was investigated in an EC Method A.10 study.

The study is a GLP-compliant, guideline experimental study and is fully acceptable for assessment of this endpoint.

Description of key information

The test item is concluded to be not highly flammable (not classified based on GHS criteria) as itignited during the two minutes of application of the burner but the flame extinguished once the burner was removed. The flame did not propagate along the train.

Key value for chemical safety assessment

Flammability:
not classified

Additional information

The flammability of the test item was investigated in a GLP-compliant EC Method A.10 study that is fully acceptable for assessment of this endpoint (Dunning 2018).

Justification for classification or non-classification

The test item is concluded to be not highly flammable (not classified based on GHS criteria) as itignited during the two minutes of application of the burner but the flame extinguished once the burner was removed. The flame did not propagate along the train.