Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
30 January 2018 - 06 February 2018
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.10 (Flammability (Solids))
Version / remarks:
2008
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Specific details on test material used for the study:
SOURCE OF TEST MATERIAL
- Source and lot/batch No.of test material: 1183806247-402
Key result
Test procedure:
burning rate test: preliminary screening test
Remarks on result:
substance does not ignite and propagate combustion either by burning with flame or smouldering along 200 mm of the powder train within the 2 minutes test period
Remarks:
The sample glowed when in contact with the ignition source. No ignition or propagation was observed

Table 1- Results of preliminary screening test

Test

Burning Time (s)

Comments

Preliminary Test

N/A

The sample glowed when in contact with the ignition source. No ignition or propagation was observed.

Interpretation of results:
not classified based on GHS criteria
Conclusions:
The test item is not highly flammable as it did not ignite in a preliminary screening test.
Executive summary:

Younis (2018) is a GLP compliant study following EU method A.10 (Flammability solids) and is considered to be reliable without restrictions (Klimisch 1). The test item is not highly flammable.

Description of key information

The test item is not highly flammable as it did not ignite in a preliminary screening test.

Key value for chemical safety assessment

Flammability:
not classified

Additional information

Younis (2018) is a GLP compliant study following EU method A.10 (Flammability solids) and is considered to be reliable without restrictions (Klimisch 1). The test item is not highly flammable.

Justification for classification or non-classification

Based on the results from a study following a standard test guideline the test item is not classified as a flammable solid as it did not ignite in the preliminary test.