Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Viscosity

Currently viewing:

Administrative data

Link to relevant study record(s)

Referenceopen allclose all

Endpoint:
viscosity
Type of information:
experimental study
Adequacy of study:
key study
Study period:
20 july 2000 - 18 january 2001
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
OECD Test Guideline 114 (Viscosity of Liquids)
GLP compliance:
yes
Type of method:
capillary viscometer (static)
Key result
Temp.:
other: 25
Parameter:
kinematic viscosity (in mm²/s)
Value:
11.4
Key result
Temp.:
other: 45
Parameter:
kinematic viscosity (in mm²/s)
Value:
8.4
Conclusions:
The kinematic viscosity of the test substance was determined using a capillary viscometer to be 11.4 mm2.s-1 at 25°C and 8.4 mm2.s-1 at 45°C.
Executive summary:

The kinematic viscosity of KATHON 886F Biocide was determined using a capillary viscometer to be 11.4 mm2.s-1 at 25°C, and 8.4 mm2.s-1 at 45°C.

Endpoint:
viscosity
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: Guideline-conform study under GLP without deviations.
Qualifier:
according to guideline
Guideline:
OECD Test Guideline 114 (Viscosity of Liquids)
GLP compliance:
yes
Type of method:
capillary viscometer (static)
Temp.:
20°C
Parameter:
dynamic viscosity (in mPa s)
Value:
4.82
Temp.:
20°C
Parameter:
kinematic viscosity (in mm²/s)
Value:
3.84
Temp.:
40°C
Parameter:
kinematic viscosity (in mm²/s)
Value:
2.29
Conclusions:
The viscosity of Aciticide 14 between 20 and 40°C was determined as
dynamic viscosity: 4.82 mPa s (20°C)
kinematic viscosity: 3.84 mm2/s (20°C) and 2.29 mm2/s (40°C)
Executive summary:

The viscosity of a mixture of 5 -chloro-2 -methyl-2H-isothiazol-3 -one and 2 -methyl-2H-isothiazol-3 -one (named Acticide 14 in this study report) was investigated according to OECD guideline 114. The static viscosity was determined in a Ubbelohde viscometer at 20 and 40 °C. The dynamic viscosity is calculated from the kinematic viscosity (due to known density at 20°C).

Description of key information

Key value for chemical safety assessment

Viscosity:
3.84 mm²/s (static)
at the temperature of:
20 °C

Additional information