Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Viscosity

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
viscosity
Type of information:
experimental study
Adequacy of study:
key study
Study period:
January 30, 2017
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
test procedure in accordance with national standard methods
Remarks:
DIN 53015 (According to Hoppler)
Qualifier:
according to guideline
Guideline:
DIN 53015 (Viscometry - Measurement of viscosity by means of the rolling ball viscometer by Höppler)
Deviations:
not specified
GLP compliance:
no
Type of method:
forced ball viscometer (dynamic)
Specific details on test material used for the study:
Name: Linseed oil, ester with pentaerythritol
Batch no.: 16.343.096
Appearance: Yellow liquid
Composition: 100% UVCB
Purity: 100% as the substance is an UVCB
Homogeneity: Homogeneous
Expiry date: October 05, 2017
Storage Room Temperature:(20 ± 5°C), After opening keep under inert gas
Key result
Temp.:
20°C
Parameter:
other: dynamic viscosity (in dPa s)
Value:
1.05
Conclusions:
Under the study conditions, the dynamic viscosity of test substance, at 20°C was found to be 1.05 dPa s (105 mPa s).
Executive summary:

A study was conducted to determine the dynamic viscosity of test substance linseed oil, ester with pentaerythritol according to DIN 53015 (According to hoppler). The dynamic viscosity was measured using hoppler forced ball viscometer. The test substance linseed oil, ester with pentaerythritol was transferred undiluted into the viscometer, after which the test sample was tempered with forced ball for 30 minutes at operating temperature of 20°C. Under the study conditions, the dynamic viscosity of test substance linseed oil, ester with pentaerythritol at 20°C was found to be 1.05 dPa s (105 mPa s).

Description of key information

The dynamic viscosity of the test substance was determined according to DIN 53015 (according to Hoppler) (Felix, 2017).

Key value for chemical safety assessment

Viscosity:
105 mPa · s (dynamic)
at the temperature of:
20 °C

Additional information